Turning the System Off
If Powerwall 3 is unresponsive, it may be necessary to turn off or power cycle the system. Note that power cycling the
system must be done in the proper sequence as defined below.
Performing a Power Cycle
1.
Turn off Powerwall 3 by setting its On/Off switch to the OFF position.
2.
Turn the Powerwall 3 integrated DC isolator OFF.
3.
Turn off the AC breaker to Powerwall 3.
4.
Turn off the AC breaker to the Gateway (for whole-home backup systems, this may be a breaker inside the
Gateway).
5.
Wait for at least one hour.
6.
Turn the AC breakers back on.
7.
Turn on Powerwall 3.
8.
Turn the Powerwall 3 integrated DC isolator ON.
WARNING: On Powerwall 3 systems with additional interconnected solar, always turn off the solar inverter(s)
or disconnect the solar source(s) before turning off Powerwall 3.