This document describes the Tesla Split-Type Air Conditioner, specifically models using R32 DC Inverter technology. It provides comprehensive information on its function, technical specifications, usage, and maintenance.
Function Description
The Tesla Split-Type Air Conditioner is designed for cooling and heating indoor spaces. It utilizes R32 DC Inverter technology, which is an environmentally friendly refrigerant with low global warming potential (GWP). The inverter technology allows for precise temperature control and energy efficiency by adjusting the compressor speed rather than cycling it on and off. The unit consists of an indoor unit and an outdoor unit, connected by refrigerant piping and electrical wiring.
Key functions include:
- Cooling and Heating: Provides both cooling and heating modes to maintain desired indoor temperatures.
- Dehumidification: Reduces humidity levels in the air.
- Fan Operation: Circulates air without cooling or heating.
- Sleep Mode: Adjusts temperature automatically during sleep for comfort and energy saving.
- Timer Function: Allows users to set specific times for the unit to turn on or off.
- Self-Cleaning (iClean): Automatically cleans the indoor unit's evaporator to prevent mold and odor.
- Anti-Fungus: Prevents the growth of mold and mildew inside the indoor unit.
- ECO Mode: Optimizes operation for maximum energy efficiency.
- iFeel Function: Uses a sensor in the remote control to measure the ambient temperature and adjust the air conditioner's operation for more precise comfort.
- Swing Function: Controls the horizontal and vertical movement of the air louvers to distribute air evenly.
- Turbo Mode: Provides rapid cooling or heating.
- Quiet Mode (Silence): Operates at a lower fan speed for reduced noise.
Important Technical Specifications
The manual lists specific models: TA22FFUL-07410IA, TA27FFUL-0932IA, TA36FFUL-1232IA, TA53FFUL-1832IA, and TA71FFUL-2432IA. These models are designed for various room sizes, indicated by their BTU ratings (e.g., 7,000 BTU to 24,000 BTU).
Refrigerant: R32, a flammable refrigerant with a low GWP. The charge amount varies by model, but for a 5M piping length, it can range from 1kg to 2kg.
Piping Length: The standard piping length is 5 meters. Additional refrigerant may be required for longer piping runs.
Electrical Specifications:
- Appliance Amps (A) and AWG (American Wire Gauge):
- 10A: AWG 18, >3 and ≤ 6 Rated Current (A), 0.75 mm² Nominal Cross-Sectional Area
- 13A: AWG 16, >6 and ≤ 10 Rated Current (A), 1 mm² Nominal Cross-Sectional Area
- 18A: AWG 14, >10 and ≤ 16 Rated Current (A), 1.5 mm² Nominal Cross-Sectional Area
- 25A: AWG 12, >10 and ≤ 16 Rated Current (A), 2.5 mm² Nominal Cross-Sectional Area
- 30A: AWG 10, >10 and ≤ 16 Rated Current (A), 4 mm² Nominal Cross-Sectional Area
- 40A: AWG 8, >10 and ≤ 16 Rated Current (A), 6 mm² Nominal Cross-Sectional Area
- Power Supply: The unit requires a dedicated power supply circuit.
- Interconnection Cord: H07RN-F or H05RN-F type.
- Minimum Cross-Sectional Area of Power Cable and Interconnection Cord: Specified in mm² based on rated current.
Installation Clearances:
- Indoor Unit: Minimum 15cm above the ceiling, 20cm to side walls, and 20-260cm to the floor.
- Outdoor Unit: Minimum 10cm above, 30cm to the left, 20cm to the front, and 50cm to the right.
Usage Features
The air conditioner is operated via a remote control, which features an LCD display and various buttons for different functions.
Remote Control Functions:
- ON/OFF Button: Turns the unit on or off.
- MODE Button: Selects operating mode (Auto, Cool, Dry, Heat, Fan).
- SPEED Button: Adjusts fan speed (Low, Mid, High, Auto).
- Temperature Adjustment Buttons (▲/▼): Sets the desired temperature in 0.5°C increments.
- TURBO Button: Activates rapid cooling or heating.
- HEALTH Button: Activates the health function (e.g., negative ion generator).
- SILENCE Button: Reduces noise level.
- SLEEP Button: Activates sleep mode.
- TIMER Button: Sets the timer for auto-on/off.
- iFEEL Button: Activates the iFeel function.
- DISPLAY Button: Turns the indoor unit's display on or off.
- iCLEAN Button: Initiates the self-cleaning function.
- Anti-F Button: Activates the anti-fungus function.
- ELE.H Button: Activates electric heating (if available).
- ECO Button: Activates energy-saving mode.
- SPOT SWING Button: Controls horizontal swing.
- SWING Button: Controls vertical swing.
- iFavor Button: Saves preferred settings for quick access.
Operation Notes:
- Temperature Range: Cooling operation is typically from 16°C to 32°C.
- Defrosting: The outdoor unit will automatically defrost during heating operation in cold weather. This is normal.
- Error Codes: The display may show error codes in case of malfunction, requiring troubleshooting.
- Smart WiFi App: The manual references a Smart WiFi app for remote control, accessible via a provided URL.
Maintenance Features
Regular maintenance is crucial for the efficient and safe operation of the air conditioner.
Cleaning and Care:
- Indoor Unit Panel: Clean with a soft, damp cloth (below 40°C) and neutral detergent. Do not use harsh chemicals like benzene or gasoline.
- Air Filter: Clean regularly (every two weeks or more frequently depending on usage). Open the front panel, remove the filters, wash them with water, and dry thoroughly before reinstalling.
- Outdoor Unit: Keep the outdoor unit clean and free from obstructions.
- Pre-season Check: Before the start of the cooling/heating season, check for blockages in air inlets/outlets, proper drainage, secure grounding, and functional remote control batteries.
Troubleshooting:
The manual provides a detailed troubleshooting guide for common issues, such as:
- No power: Check power supply, fuse, and circuit breaker.
- Unit not starting immediately: This is normal for protective delays.
- Unit stops running for a while: May be due to reaching set temperature or defrosting.
- Poor cooling/heating effect: Check for dirty filters, blocked air inlets/outlets, open doors/windows, and correct mode/temperature settings.
- Indoor unit odor: Clean the air filter and indoor unit.
- Water running noise: Normal for refrigerant flow.
- Clicking sound: Normal for temperature changes and panel expansion/contraction.
- Abnormal noise/vibration: Check for loose parts or obstructions.
- Water drips on surface: Normal for condensation.
- Mist blowing out: Normal for rapid cooling/heating.
Installation and Repair:
- Professional Installation: Installation and major repairs should be performed by qualified professionals due to the use of flammable R32 refrigerant and high voltage.
- Leakage Check: Regular checks for refrigerant leaks are essential, especially during installation and maintenance. The manual describes methods like bubble testing and using a leak detector.
- Vacuum Pumping: Essential during installation to remove non-condensable gases and moisture from the refrigerant circuit.
- Electrical Safety: Ensure proper grounding and use of specified wiring.
- Disposal: The unit contains recyclable materials and should be disposed of according to local regulations for electronic waste.
Safety Precautions:
The manual emphasizes several warnings and cautions:
- Flammable Refrigerant (R32): Handle with extreme care. Do not use methods to speed up defrosting or clean frost that are not recommended by the manufacturer. Do not pierce or burn the air conditioner.
- Electrical Safety: Do not connect the earth wire to gas pipes, telephone wires, or lightning rods. Ensure proper grounding. Do not operate with wet hands.
- Maintenance: Only qualified personnel should perform maintenance and repairs.
- Children and Vulnerable Persons: The appliance can be used by children aged 8 and above and persons with reduced physical, sensory or mental capabilities if supervised and instructed on safe use.
- Installation Environment: Avoid installing near heat sources, flammable gases, or in areas with poor ventilation.
- Piping: Ensure refrigerant piping is securely connected and free from damage.
- Storage: Store in a well-ventilated area, away from heat sources and open flames.