Temperature Range | 0°C to +60°C |
---|---|
Temperature Uniformity | ±0.5°C |
Temperature Stability | ±0.3°C |
Interior Dimensions (W x H x D) | 24" x 24" x 24" |
Shelves | 2 adjustable shelves |
Heating Rate | 3°C per minute |
Cooling Rate | 1°C per minute |
General safety information and hazard symbols for safe operation.
Safety requirements for chamber setup, placement, and environmental conditions.
Crucial safety warnings for daily use, potential hazards, and precautions.
Steps to safely remove the chamber from its shipping pallet and packaging.
Initial inspection and setup steps before operating the chamber.
Environmental and clearance requirements for proper chamber placement.
How to correctly set up the chamber's electrical input voltage and phase.
Detailed steps for configuring voltage and phase settings for operation.
Procedures for connecting the chamber to the main AC power supply.
Guidance on connecting the demineralized water supply for humidity control.
Overview of chamber controls and basic operation steps.
Description of switches and indicator lights on the front panel.
Guidelines for placing samples and factors affecting performance.
How to use humidity control and optional purge systems.
The role of the EZ-Zone Limit Controller as a protective safety device.
Explanation of the controller's interface, buttons, and indicators.
Procedure to configure high and low temperature trip points for safety.
How to clear an alarm after a temperature limit has been exceeded.
Using safety contacts for external test sample protection.
Clarifying voltage compatibility and power cord installation requirements.
Considerations for operating the chamber outside North America.
Explanations for variations in heating/cooling performance from specifications.
Details on temperature accuracy, uniformity, and safe unit movement.
Procedures for preparing the chamber for storage or restart.
Answers to common questions about refrigerants and system charging.
Key metrics: temp range, control, uniformity, and load capacity.
Specifications for time taken to reach target temperatures.
Power requirements, dimensions, clearance, and weight.
Schedule for daily, 3-month, 6-month, 12-month maintenance tasks.
Step-by-step guides for cleaning, inspections, and draining systems.
Inspecting the compartment and checking refrigerant charge.
Tests to confirm the chamber meets operating specifications.
Methods for checking temperature and humidity calibration.
Explanation of chamber's heating, humidity, and refrigeration systems.
Identifying and resolving common chamber issues.
Procedures for charging refrigerants.
List of critical spare parts for electrical and refrigeration components.
Details of TestEquity's limited warranty, coverage, and exclusions.
Diagram showing the layout of components within the electrical subpanel.