EasyManua.ls Logo

TESTO 735 User Manual

TESTO 735
56 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Bedienungsanleitung de
Instruction manual en
Inhalt
Allgemeine Hinweise ............................................2
1. Sicherheitshinweise..............................................4
2. Bestimmungsgemäße Verwendung ......................5
3. Produktbeschreibung ..........................................6
3.1 Anzeige- und Bedienelemente ........................................6
3.2 Schnittstellen ..................................................................8
3.3 Spannungsversorgung ....................................................8
4. Inbetriebnahme ....................................................9
5. Bedienung..........................................................10
5.1 Fühler anschließen ........................................................10
5.2 Ein- / Ausschalten ........................................................10
5.3 Displaybeleuchtung ......................................................11
6. Gerät einstellen ..................................................12
6.1 Konfigurationsmenü ......................................................12
6.1.1 Profil................................................................................12
6.1.2 Einheiten ........................................................................13
6.1.3 Gerät ..............................................................................13
6.1.4 Fühler..............................................................................14
6.1.5 Language........................................................................16
6.2 Hauptmenü ..................................................................17
6.2.1 Speicher (nur 735-2 ) ......................................................18
6.2.2 Messreihe (nur 735-2 ) ..................................................19
6.2.3 Mittelwert ......................................................................20
6.2.4 Zyklisch Drucken (nur 735-1) ..........................................20
6.2.5 Alarm ..............................................................................21
7. Messen ..............................................................22
8. Wartung und Pflege............................................24
9. Fragen und Antworten........................................25
10. Technische Daten ..............................................26
11. Zubehör / Ersatzteile ..........................................27
testo 735
Temperatur-Messgerät
1.888.475.5235info@Testo-Direct.com
w ww.Testo-Direct.com
Question and Answer IconNeed help?

Do you have a question about the TESTO 735 and is the answer not in the manual?

TESTO 735 Specifications

General IconGeneral
Resolution0.1 °C
DisplayLCD
Data Storage10, 000 readings
Dimensions220 x 74 x 46 mm
Weight428 g
Protection ClassIP65
Channels3
Battery LifeApprox. 200 hours
Probe TypeThermocouple

Summary

General notes

Safety instructions

Intended purpose

Product description

Display and control elements

Overview of the instrument's display and control buttons.

Interfaces

Details on infrared, USB, and probe socket interfaces.

Voltage supply

Information on power sources, batteries, and mains units.

Commissioning

Inserting batteries and radio module

Steps for inserting batteries and optional radio module.

Operation

Connecting a probe

Instructions for connecting plug-in and radio probes.

Switching on/off

Procedure for powering the instrument on and off.

Display light

How to turn the instrument's display light on and off.

Setting the instrument

Configuration menu

Accessing and navigating the instrument's configuration menu.

Profile

Setting measurement profiles to tailor instrument functions.

Units

Selecting measurement units for temperature.

Device

Viewing instrument data like firmware and serial number.

Date/Time

Setting the instrument's date and time.

Battery type

Setting the battery type for accurate capacity display.

Auto OFF

Configuring the automatic switch-off function.

Reset

Resetting the instrument to default settings.

Setting min. / max. printing function

Enabling printing of min/max values with measurements.

RadioC

Procedure for setting up radio probes with channel assignment.

Te-Type

Setting the probe characteristic curves.

Adjustment (735-2 only)

Activating/deactivating probe adjustment data.

Language

Setting the instrument's display language.

Main menu

Overview of functions available in the main menu based on profile.

Memory (735-2 only)

Managing memory, changing location, and printing protocols.

Measuring program (735-2 only)

Programming and activating automatic measuring programs.

Mean

Information on mean value calculation for testo 735-2.

Cyclical Print (735-1 only)

Activating cyclical printing and programming measurement programs.

Alarm

Setting alarm thresholds and configuring alarm tones.

Setting alarm thresholds

Detailed steps for setting upper and lower alarm thresholds.

Measuring

Taking a measurement

Steps to perform a measurement with the instrument.

Changing display lines

How to change upper and lower measurement display lines.

Resetting max./min. values

Procedure to reset recorded maximum and minimum values.

Holding readings

How to hold current readings and revert to actual readings.

Saving readings (735-2 only)

Steps to save measurement readings.

Timed mean calculation

Forming a timed mean value from measurements.

Multi-point mean calculation

Forming a multi-point mean value from measurements.

Running AUTO measuring program (735-2)

Running the automatic measuring program and its criteria.

Cyclical printing (735-1 only)

Starting cyclical printing and data transmission.

Care and maintenance

Cleaning the housing

Instructions for cleaning the instrument's housing.

Changing the battery/rechargeable battery

Steps to replace batteries or rechargeable batteries.

Questions and answers

Instrument lights up

Troubleshooting for when the instrument lights up.

Instrument switches off automatically

Troubleshooting for unexpected automatic power-off.

Display: -----

Troubleshooting for specific display error messages.

Display: uuuuu

Troubleshooting for specific display error messages.

Display: 00000

Troubleshooting for specific display error messages.

Instrument settings incorrect

Troubleshooting for incorrect instrument settings.

Technical data

Measuring ranges and accuracies

Specifications for measuring ranges and accuracy across probe types.

Further instrument data

Details on probe connections, memory, battery life, and power supply.

Accessories/spare parts

Probes

List of available accessory probes with part numbers.

Miscellaneous

List of miscellaneous accessories like mains units and chargers.

Related product manuals