Added Features
www.ti.com
10
SLUUBM6March 2018
Submit Documentation Feedback
Copyright © 2018, Texas Instruments Incorporated
Overview
3.2.5.3 Current Med
Class Subclass Name Type Min Max Default Unit
Advanced Charging
Algorithms
High Temp
Charging
Current Med I2 0 32767 1980 mA
Description: High temperature range medium voltage range ChargingCurrent()
3.2.5.4 Current High
Class Subclass Name Type Min Max Default Unit
Advanced Charging
Algorithms
High Temp
Charging
Current High I2 0 32767 1496 mA
Description: High temperature range high voltage range ChargingCurrent()
3.2.6 Recommended Temp Charging
3.2.6.1 Voltage
Class Subclass Name Type Min Max Default Unit
Advanced Charging
Algorithms
Rec Temp
Charging
Voltage I2 0 32767 4100 mV
Description: Recommended temperature range ChargingVoltage()
3.2.6.2 Current Low
Class Subclass Name Type Min Max Default Unit
Advanced Charging
Algorithms
Rec Temp
Charging
Current Low I2 0 32767 2508 mA
Description: Recommended temperature range low voltage range ChargingCurrent()
3.2.6.3 Current Med
Class Subclass Name Type Min Max Default Unit
Advanced Charging
Algorithms
Rec Temp
Charging
Current Med I2 0 32767 4488 mA
Description: Recommended temperature range medium voltage range ChargingCurrent()
3.2.6.4 Current High
Class Subclass Name Type Min Max Default Unit
Advanced Charging
Algorithms
Rec Temp
Charging
Current High I2 0 32767 3520 mA
Description: Recommended temperature range high voltage range ChargingCurrent()
3.2.7 Pre-Charging
Pre-Charging Current is retained, while Start Voltage and Recovery Voltage are removed.