www.ti.com
Added Features
7
SLUUBM6March 2018
Submit Documentation Feedback
Copyright © 2018, Texas Instruments Incorporated
Overview
3.2.1.3 T5 Temp
Class Subclass Name Type Min Max Default Unit
Advanced Charging
Algorithms
Temperature
Ranges
T5 Temp I1 –128 127 20 °C
Description: T5 recommended temperature range lower limit
3.2.1.4 T6 Temp
Class Subclass Name Type Min Max Default Unit
Advanced Charging
Algorithms
Temperature
Ranges
T6 Temp I1 –128 127 25 °C
Description: T6 recommended temperature range upper limit
3.2.1.5 T3 Temp
Class Subclass Name Type Min Max Default Unit
Advanced Charging
Algorithms
Temperature
Ranges
T3 Temp I1 –128 127 30 °C
Description: T3 standard temperature range to high temperature range
3.2.1.6 T4 Temp
Class Subclass Name Type Min Max Default Unit
Advanced Charging
Algorithms
Temperature
Ranges
T4 Temp I1 –128 127 55 °C
Description: T4 high temperature range upper limit
3.2.1.7 Hysteresis
Class Subclass Name Type Min Max Default Unit
Advanced Charging
Algorithms
Temperature
Ranges
Hysteresis Temp I1 –128 127 1 °C
Description: Temperature Hysteresis, applied when temperature is decreasing.
3.2.2 Fast Charging
Fast Charging Voltage and Current is replaced with:
Low Temp Charging Voltage
Low Temp Charging Current Low
Low Temp Charging Current Med
Low Temp Charging Current High
Standard Temp Charging Voltage
Standard Temp Charging Current Low
Standard Temp Charging Current Med
Standard Temp Charging Current High
High Temp Charging Voltage

Other manuals for Texas Instruments bq78350-R1