EasyManua.ls Logo

Texecom PREMIER 48 - Udl;Digi Options

Texecom PREMIER 48
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Premier 48, 88 & 168 Factory Defaults and Quick Reference Guide Factory Defaults
INS222 3
Menu Option Default
3. Global Options Continued
Config. Options 31: Clock = Crystal 50Hz
Continued 32: 40 Column Print 80
33: Enable Text Disable
34: EN50131 Disabled Enabled
35: 1st Zone=Confirm 2nd
36: Keypads Local Global
37: Panel Grade 2 Grade 3 *
38: Enable RF FOB PA
Disable
39: Mask When Armed
Fault
System Options 1: Advisory Volume 6
2: Chime Volume 3
3: No. of Re-Arms 03
4: Anti-code Resets 03
5: Multi Knocks 05
6: Clock Adjustment 50 (no adjustment)
7: Quick Count 4
8: Modem Level 0
Monitor Hardware 1: Phone Line Fault Enabled
2: Power Failure Enabled
3: Aux Fuse Blown Enabled
4: Bell Tamper Enabled
5: Aux Tamper Enabled
6: Panel Lid Tamper Enabled
7: Battery Faults Enabled
Control Timers 1 – 8 Not Defined
System Text Reset Message Call Engineer to
Reset System
Anti-code Message Call ARC Centre
to Reset System
Service Message Call Alarm Co.
For Service
Location Text No Location Text
Has Been Setup
Banner Message Not Defined
Part Armed Banner * PART ARMED *
Printer Header Not Defined
Part Arm Text Part Arm 1 Evening Arm
Part Arm 2 Bedtime Arm 1
Part Arm 3 Bedtime Arm 2
Holiday Dates 1 - 8 Not Defined
Speaker Tones All Tones Enabled
PC Output Text All Text Not Defined
Custom O/P Text All Text Not Defined
4. Keypad Setup
Areas All Keypads Area A
Zone Mapping All Keypad zones Not Mapped
Options 1: PA Enabled Disabled
2: Fire Enable Disabled
3: Medical Enabled Disabled
4: Tamper Disabled Enabled
5: PA Audible Silent
6: PA Delayed Instant
7: Quick Arm Keys Off
8: Info.LED> Output Armed
Volume All Keypads 4
Sounder Options All Tones Enabled
5. Expander Setup
Areas All Expanders Area A
Text All Expanders Not Defined
Auxiliary Input All Expanders Not Used
Volume All Expanders 4
Sounder Options All Tones Enabled
Menu Option Default
6. Output Setup
Panel Outputs 1 - 5 Not Used
Digi Outputs 1 *** Tamper *
2 *** Fault Present *
3 *** AC Mains Fail *
4 *** Not Used *
5 *** Not Used *
6 *** LED Control *
7 *** Armed *
8 *** Detector Test *
Com? Channels 1 Fire
2 PA
3 Alarm
4 Armed
5 Zones Locked Out
6 Not Used
7 Confirmed Alarm
8 Abort
RedCARE Pins 1 Fire
2 PA
3 Intruder Alarm
4 Armed
5 Zones Locked Out
6 Abort
7 Confirmed Alarm
8 Not Used
Keypads 1-8 Outputs LED Control LED Control
Expanders 1-8 Outputs 1 LED Control
2 Armed
3 Detector Test
4 - 8 Not Used
Custom O/P 1 1 Control Timer 1
2 - 8 Not Used
Custom O/P 2 1 - 4 Not Used
5 Entry
6 Not Used
7 - 8 Always ON
Custom O/P 3 1 - 8 Not Used
Custom O/P 4 1 - 8 Not Used
X-10 Outputs 1 - 8 Not Used
7. UDL/Digi Options
Reset Digi N/A N/A
Test Com? N/A N/A
Set Call Waiting Number Not Defined
Program Digi ARC 1 Not Defined
ARC 2 Not Defined
ARC 3 Not Defined
Digi Options Digi is Enabled Disabled
Pulse Dialling Tone
Pulse After 3 Always Tone
Blind Dialling Wait Dial Tone
Call Waiting On Off
Dial All Numbers Dial Any
UDL Options Call Back Number 1 Not Defined
Call Back Number 2 Not Defined
Call Back Number 3 Not Defined
UDL Password Not Defined
DL Attended Unattended
Auto Call-Back Manual
Call Defeat Off On
DL Arm Limited At Anytime
Any Area Armed Fully Armed
DL Keypad not OK OK
Rings Required 005
UDL Dial Attempts 003
Area Accounts All Areas Not Defined

Other manuals for Texecom PREMIER 48

Related product manuals