INS545-2 20/49
2.0 EN: Installation Sheet
Product description
The Premier Elite MR/MR Long Range and PW are designed to detect movement of
an intruder and activate an alarm control panel. The product is intended to be
connected to a listed burglar compatible control unit or a power supply that has a
voltage output range of between 9 to 15 VDC and provides a minimum of 4 hours
of standby power.
1. Installation guidelines
The technology used in these detectors resists false alarm hazards. However, avoid
potential causes of instability such as (see Fig. 1).
2. Opening the detector
Unwind the screw at the base of the detector until loose; the screw will be retained
in the product (see Fig. 2, step1).
Lift detector lid out from the base and off the lugs at the top (see Fig. 2, step 2).
3. Remove the chassis
4. Detector Knockouts
5. Mounting the detector
6. Coverage & Pick-up
7. Premier Elite MR/MR Long Range
Latch Input / First to Alarm
The FTA terminal can perform several different functions depending on how it
is connected:
Latch connected to Set Positive (SW+, Set+): The LEDs will be disabled while
the system is set. Any detectors triggered while the system is set will indicate
this by permanently lighting the alarm LED (upon unsetting the system).
Detectors can be reset by taking the latch line high and then low again.