AC Current
Range (50 Hz to 400 Hz) Accuracy Burden Voltage (typical)
600.0 µA ± (1.0% + 0.3 µA)
0.1 mV/µA
6000 µA ± (1.0% + 3 µA)
60.00 mA ± (1.0% + 0.03 mA)
1.7 mV/mA
600.0 mA ± (1.0% + 0.3 mA)
6.000 A ± (1.2% + 0.006 A)
0.03 V/A
8.00 A* ± (1.8% + 0.006 A)
Accuracies for DM-510A are specified from 5% to 100% of range
* 8 A continuous, > 8 A to 15 A for 30 second max with 5 minutes cool down interval
DC Current
Range Accuracy Burden Voltage (typical)
600.0 µA ± (0.5% +0.5 µA)
0.1 mV/µA
6000 µA ± (0.5% + 3 µA)
60.00 mA ± (0.5% + 0.05 mA)
1.7 mV/mA
600.0 mA ± (0.5% + 0.3 mA)
6.000 A ± (1.2% + 0.006 A)
0.03 V/A
8.00 A* ± (1.8% + 0.006 A)
*
8 A continuous, > 8 A to 15 A for 30 second max with 5 minutes cool down interval
Frequency —Hz (Line) at ACV, DCV, Current, AutoCheck™ Mode
Function Sensitivity (SineRMS) Range
6 V 0.4 V 10 Hz to 10 kHz
60 V 4 V 10 Hz to 50 kHz
600 V 40 V 10 Hz to 50 kHz
1000 V 400 V 45 Hz to 1 kHz
600 µA 40 µA 10 Hz to 10 kHz
6000 µA 400 µA 10 Hz to 10 kHz
60 mA 4 mA 10 Hz to 10 kHz
600 mA 40 mA 10 Hz to 10 kHz
6 A 1 A 10 Hz to 1 kHz
10 A 6 A 10 Hz to 1 kHz
Accuracy (cont’d)