EasyManua.ls Logo

Textron Greenlee DM-200A User Manual

Textron Greenlee DM-200A
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INSTRUCTION MANUAL
52047798 REV 1 © 2014 Greenlee Textron Inc. 3/14
DM-200A • DM-210A
DM-510A
Digital Multimeters
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
Question and Answer IconNeed help?

Do you have a question about the Textron Greenlee DM-200A and is the answer not in the manual?

Textron Greenlee DM-200A Specifications

General IconGeneral
TypeDigital Multimeter
DisplayLCD
Max Voltage600V
Max Current10A
Resistance MeasurementYes
Capacitance MeasurementYes
Frequency MeasurementYes
Battery9V
DC Voltage600V
AC Voltage600V
DC Current10A
Diode TestYes
Continuity TestYes
Safety RatingCAT III 600V
Battery Type9V
Display Digits3.5
Voltage Range (DC)200mV to 600V
Current Range (AC)200µA to 10A
Current Range (DC)200µA to 10A

Summary

Safety Precautions

Essential Safety Guidelines

Emphasizes the importance of safety in using and maintaining Greenlee tools.

Important Safety Information

Environmental and Usage Hazards

Prohibits exposure to rain, moisture, or use when wet or damaged.

Measurement Procedure Safety

Advises shutting off power, discharging capacitors, and correct lead connection.

Hazard Severity Levels

Defines DANGER, WARNING, and CAUTION levels to indicate hazard severity.

Voltage Limit and Contact Precautions

Warns against exceeding rated voltage and contacting uninsulated parts.

Function Change Hazards

Warns against changing measurement functions while leads are connected.

Pre-Operation Safety Guidelines

Advises users to read and understand the material before operating the equipment.

Case Open Operation Prohibition

Instructs users not to operate with the case open and to disconnect power first.

AutoCheck™ Mode Circuit Caution

Caution against measuring voltages in circuits sensitive to low input impedance.

Electric Shock Hazard Warning

Warns about the severe injury or death risk from contact with live circuits.

Fuse Protection Importance

Highlights fuses as integral to overvoltage protection and warns against using incorrect types.

Repair and Environmental Limits

States the unit has no user-serviceable parts and warns against extreme temperatures.

Using the Features

Using the Features (cont'd)

AC Measurement Explained

Meter Operation

Meter Operation (cont'd)

Typical Measurements

Typical Measurements (cont'd)

Accuracy Specifications

AC Voltage Accuracy Table

Details accuracy for AC voltage measurements across different ranges.

DC Voltage Accuracy Table

Details accuracy for DC voltage measurements across different ranges.

Resistance Accuracy Table

Details accuracy for resistance measurements across different ranges.

Accuracy Specifications (cont'd)

AC Current Accuracy Table

Details accuracy for AC current measurements across different ranges.

Frequency Range Accuracy Table

Details accuracy for various frequency measurement ranges.

DC Current Accuracy Table

Details accuracy for DC current measurements across different ranges.

Frequency-Hz (Line) Accuracy Table

Specifies accuracy for line-level frequency measurements.

DM-510A AutoCheck™ Accuracy

Specifies accuracy for DM-510A's AutoCheck™ modes (ACV, DCV, Resistance).

General Specifications

Measurement Categories

Maintenance Procedures