Cautions
• Protect the unit from EMI (Electro Magnetic Interference) from induction
heaters and microwave ovens and Electro Static Discharge. Readings may be
affected if the unit is operated within a radio frequency electromagnetic
field strength of approximately 3 volts per meter, but the performance of the
instrument will not be permanently affected.
• Protect the unit from “thermal shock” (caused by large or abrupt ambient
temperature changes).
• Do not leave the unit on or near objects of high temperature.
• Not recommended for taking human temperature.
Reminders
• Not recommended for use in measuring shiny or polished metal surfaces
(stainless steel, aluminum, etc.).
• The unit cannot measure through transparent surfaces such as glass or plastic.
It will measure the surface temperature of the glass instead.
• Steam, dust, smoke, etc., can prevent accurate measurement by obstructing
the unit’s optics.
Care and Cleaning
• The Sensor Lens is the most delicate part of the thermometer. Please protect
the sensor part from dirt. Gently clean it with a soft cloth moistened with
water or medical alcohol.
• Avoid splashes and spills on the unit.
• Store at a temperature of between -20°C to +65°C.
Specifications
Temperature range -33°C to 250°C (-27°F to 482°F)
Accuracy ±2°C or 2%, whichever is greater
Resolution 0.1°C / 0.1°F
Response time ca. 1 second
Operating environment 0 to +50°C
Emissivity 0.95 default (adjustable 0.01 to 1)
Optical resolution 6:1 (D : S)
Battery 2 x button cell CR2032
Case plastic
Dimension 22.5 x 60 x 104 mm
Weight 63 g
LASER RADIATION
DO NOT STARE INTO BEAM!
CLASS 2 LASER PRODUCT
MAX. OUTPUT < 1 mW, WAVELENGTH 635 – 650 NM
TFA No. 31.1114 Anleitung 14.09.2005 14:40 Uhr Seite 9