CS78421-548-754
IMPORTANT NOTE:
Read this manual carefully before installing
or operating your new air conditioning
unit. Make sure to save this manual for
future reference.
SPLIT-TYPE ROOM AIR CONDITIONER
Installation Manual
Dream Inverter Series
All Model Numbers

Questions and Answers

Summary

Safety Precautions

Accessories

Installation Summary - Indoor Unit

Unit Parts

Indoor Unit Installation

Installation Instructions - Indoor Unit

General instructions for installing the indoor unit, including location selection criteria and restrictions.

Mounting Plate Dimensions

Details on dimensions and specifications of mounting plates for different indoor unit models.

Connect Signal Cable

Instructions for connecting the signal cable between indoor and outdoor units, including cable type and size selection.

Outdoor Unit Installation

Installation Instructions - Outdoor Unit

General instructions for installing the outdoor unit, focusing on location selection standards.

Weather Considerations

Guidance on selecting outdoor unit location based on weather conditions like wind, rain, and salty air.

Unit Mounting Dimensions

Specifications for mounting dimensions of various outdoor unit sizes for ground or wall bracket installation.

Connect Signal and Power Cables

Instructions for connecting signal and power cables to the outdoor unit, adhering to electrical regulations.

Refrigerant Piping Connection

Connection Instructions - Refrigerant Piping

Detailed steps for cutting, removing burrs, flaring, and connecting refrigerant pipes properly.

Air Evacuation

Preparations and Precautions

Essential checks and precautions before performing air evacuation to prevent system damage.

Evacuation Instructions

Step-by-step guide for performing air evacuation using manifold gauge and vacuum pump.

Electrical and Gas Leak Checks

Electrical Safety Checks

Procedures for verifying electrical safety, grounding, and leakage after installation.

Gas Leak Checks

Methods for detecting refrigerant leaks at connection points using soap water or a leak detector.

Test Run

Test Run Instructions

Steps to follow for performing a test run, including checks for electrical, leaks, and operational functions.