CALIBRATION WITH VERIFIED WEIGHTS (CAL 1)
Section 4.1 in the user manual
Ensure that there is no unwanted weight on the system and that you
are in the configuration level.
Using the or keys scroll from dEF until you see CAL 1.
Press when you see CAL 1 and you will then see 0Ero,
Press again and you will see the preset coefficient value
Press again you should see -CALI- flashing which will store this as
your zero point.
Once it has stored this value it will return to 0ERo.
Press on 0ERo you will see SPAn.
Place your verified weight onto your scale and press where you will
see a value displayed.