13
ASSESSMENT.
Ensure fire is cool before commencing any work.
Ensure batteries are new, mounted correctly, and connections are good.
Start with the valve in standby position slide switch in ON (I) position, red light on valve off, and fire burner
also off.
Press the power button, marked , and hold for approx. 1 second, or until the red LED lights up, then release.
This should start the ignition sequence, and within a few seconds a repetitive spark should be produced at the
electrode.
The fire may make up to 3 automatic attempts to ignite. Each ignition cycle takes 15-30 seconds, with a pause
of approx. 10 seconds between each cycle. Multiple attempts DOES NOT signify that there is a fault, each fire
and installation is unique, and may account for this.
If the fire fails to ignite after 3 automatic cycles, the red light on the valve will stay permanently lit, indicating
valve lockout. A connected display handset will also return the error code E00. To reset the lockout press the
power button to return the valve to standby, and try normal start-up process again.
If problem persists, and valve repeatedly goes to lockout, refer to the cleaning and maintenance section. It is
possible that the valve has become contaminated with debris, and requires cleaning to restore normal
operation.
If the fire does not light and/or
There is an error code EXX (where XX is a two-digit number) displayed on the handset.
The red LED on the valve is flashing like a heartbeat.
The display handset is showing low battery.
…check troubleshooting section and error codes section for further information.