OWNER’S
MANUAL
& INSTALLATION GUIDE
MODELS 135THM4N | 135THM4P
170THM4N | 170THM4P
4 Star Gas Hot Water Heater
Specifications and materials may change without notice.
Eective for all Thermann 4 star water heaters manufactured
and sold after 1st December 2013.
For advice, repairs and service,
call: 1800 080 055
Carefully remove all packaging and
transit protection from the heater
before installation. Dispose of the
packaging responsibly using re-
cycling facilities where they exist.
Installation Details
Owners Information
Warranty
H4127 Rev. B
Question and Answer IconNeed help?

Do you have a question about the Thermann 135THM4N and is the answer not in the manual?

Thermann 135THM4N Specifications

General IconGeneral
BrandThermann
Model135THM4N
CategoryWater Heater
LanguageEnglish

Summary

OWNER'S MANUAL & INSTALLATION GUIDE

Installation Details

Outdoor Tank Installation

The water heater must be installed outdoors, with minimum clearances as shown in the figure.

Plumbing Connections

Installation Requirements

Must be installed by a licensed tradesperson according to AS/NZS3500.4, AS/NZS 5601.1, and local regulations.

Pressure & Temperature Relief Valve

Details the PTR valve, its rating (1400kPa), installation, and maintenance requirements.

Temperature Protection

Mandatory fitting of a temperature control device to reduce scald injury risk, requiring regular checks.

Gas Connections

Lighting the Water Heater

Step-by-step instructions for lighting the pilot and main burner, including safety precautions.

Specifications

Tank Specifications

Includes Model Numbers, Capacity (L), Net Weight Empty (kg), Relief Valve Pressure (kPa), Gas Consumption.

Commissioning Adjustments

Main Gas Pressure Regulator Adjustment

The main burner pressure must be set at installation and checked using a water manometer or equivalent.

Owner's Information

Water Quality

Discusses suitability for Australian metropolitan supplies and the effect of Total Dissolved Solids (TDS) on the heater.

System Maintenance

Five Year Service – By Authorised Personnel Only

Details the mandatory 5-year service by a licensed tradesperson, including valve and anode replacement.

Troubleshooting

What Should I Check Before Making A Service Call?

Points to consider for insufficient hot water, including usage, burner status, and valve discharge.

Warranty

Conditions of Warranty and Replacement Guarantee

Benefits provided by warranty and guarantee, in addition to ACL rights, and exclusions.

Terms of Warranty and Replacement Guarantee

Details the 1-year full parts and labour warranty and the 7-year inner cylinder replacement guarantee.