TECHNICAL DATA - TANK
Tank Specifications
WATER SUPPLY QUALITY
CHLORIDE, WATER HARDNESS AND PH
In high chloride water supply areas, the water can corrode some parts and cause them to
fail. Where the chloride level exceeds 200 mg/litre or Water Hardness level exceeds 200
mg/litre, warranty does not apply to the heat pump unit and tank unit. pH is a measure
of whether the water is alkaline or acidic. In an acidic water supply, the water can corrode
some parts and cause them to fail.
No warranty applies to the heat pump unit and tank unit where the pH is less than 6.5 or
more than 8. The water supply from a rainwater tank unit in a metropolitan area is likely to
be corrosive due to the dissolution of atmospheric contaminants.
Water with a pH less than 6.5 may be treated to raise the pH. It is recommended that an
analysis of the water from a rainwater tank be conducted before connecting this type of
water supply to the system.
350
300
250
200
150
100
50
4 5
acidic
6 7
pH
8 9
Chloride, Water Hardness
pH
&
Chloride and Water Hardness
No Warranty Applies
to the Heat Pump Unit or Tank Unit
No Warranty Applies
to the Heat Pump Unit or Tank Unit
Within Warranty
Specification
0
alkaline
Figure: Water Hardness
CHANGE OF WATER SUPPLY
Changing, or alternating, from one water supply to another can have a detrimental
eect on the operation and/or life expectancy of the water tank unit cylinder, PTR valve,
water heating circulation and the water heat exchanger in the system. Where there is
a changeover from one water supply to another, for example, a rainwater tank supply,
desalinated water supply, public reticulated water supply or water brought in from another
supply, then water chemistry information should be sought from the supplier or the water
should be tested to ensure it meets the warranty requirements in this installation manual.
Total volume 323L Diameter 613mm
Tank unit weight (empty) 92kg Height 1763mm
PTRV pressure rating 850kPa Hot water outlet
1535mmSensor level on tank 69% PTR valve
Heat pump return
Sensor 555mm
Cold Water inlet
201mm
Heat Pump Flow
RTN