Maintenance Inspection Schedule
36
DPF STRUCTURAL
• • • Visually inspect DPF canister and exhaust system components for leaks, damaged,
loose or broken parts.
• • Drain air inlet hose condensation trap.
• • • Inspect air inlet and air outlet hoses for kinks or damage.
• • Torque DPF mounting straps to 110 in-lb (12 N•m).
• • Check valve box cover is tightly secured.
• • • Check valve box for cracks, air leaks, damage or loose mounting bolts.
Pre-Trip 500
Hrs
Annual
2,000
Hrs
Inspect/Service These Items