Thermo Scientific
ThermoFlex
TM
Recirculating Chillers
(Basic Controller)
Thermo Scientic Manual P/N U00933
Rev. 11/03/2017
Visit our Web site at:
http://www.thermofisher.com/tc
Product Service Information, Applications
Notes, SDS Forms, e-mail.
Voice Info: (800) 258-0830
Multilingual Quick
Start Guides
Multilingual Essential
Safety Instructions
Installation
Operation
Preventive
Maintenance
Troubleshooting

Table of Contents

Questions and Answers

  • S
    Sheila NolanAug 8, 2025
    How to troubleshoot a Thermo Scientific ThermoFlex24000 that will not start?
    • J
      James Erickson Jr.Aug 8, 2025
      If your Thermo Scientific Chiller won't start, begin by inspecting the electrical connections. If it's the first time you're using it, refer to the quick start instructions. Check the controller for any error codes. Also, make sure the optional GFCI breaker on the rear is in the up position. For ThermoFlex900 - 10000 chillers, ensure the circuit protector is in the on ( I ) position. Confirm that the supply voltage is connected and matches the chiller's nameplate rating ±10%. If there's no display or it shows 8888 on ThermoFlex900 - 10000, try recycling the circuit protector on the rear.
  • R
    Russell BonillaAug 28, 2025
    How to fix inadequate temperature control on a Thermo Scientific ThermoFlex24000?
    • S
      Susan VargasAug 28, 2025
      To address inadequate temperature control in your Thermo Scientific Chiller, start by verifying the setpoint. If the chiller is over-cooling, recycle the power. Ensure the condenser/air filter is free of dust and debris, and confirm the chiller installation complies with site requirements. Check that the supply voltage matches the chiller's nameplate rating ±10%. For ThermoFlex900 - 5000 global voltage chillers, make sure the chiller is properly configured. If the temperature continues to rise, ensure your application's heat load does not exceed the rated specifications. Also, check for high thermal gradients and verify/adjust controller PID values.
  • C
    Christopher MurphyNov 18, 2025
    What to do if my Thermo Scientific ThermoFlex24000 shuts down unexpectedly?
    • B
      bryansandersNov 18, 2025
      If your Thermo Scientific Chiller shuts down, first ensure that wasn't accidentally pressed. Check that the optional GFCI breaker on the rear is in the up position and, for ThermoFlex900 - 10000 chillers, that the circuit protector is in the on ( I ) position. Examine the controller for error codes. Remember the chiller is designed to shut down if not properly primed. Confirm the supply voltage matches the chiller's nameplate rating ±10%, and then restart the chiller. If there is inadequate pump pressure, ensure any user installed in-line valves are in the desired position. Also, ensure the chiller’s process fluid outlet is connected to the application’s fluid inlet and not the application’s fluid outlet. All connections should be secure, using the proper sealant/lubricant for the fitting ...

Summary

Chiller Overview and Quick Start

General Safety Guidelines

Essential safety precautions and warnings for chiller operation and handling.

Installation and Operation Introduction

Key sections for chiller installation, operation, and maintenance.

Section 1 Safety

Safety Warnings

Details critical safety warnings and precautions for operating the chiller.

Section 2 General Information

Product Description and Specifications

Provides a general overview of the chiller and lists its technical data.

Section 3 Installation

Installation Requirements

Covers site, electrical, plumbing, and fluid requirements for chiller installation.

Section 4 Operation

Basic Controller Operation and Setup

Overview of the controller interface, setup, start-up, and loop navigation.

Section 5 Options and Accessories

Additional Options and Accessories

Details available options like Auto Refill, DI Filters, and pressure relief valves.

Section 6 Preventive Maintenance

Preventive Maintenance Procedures

Covers maintenance timer, filter replacement, reservoir cleaning, and fluid maintenance.

Section 7 Troubleshooting

Operational Error Codes

List of error codes, their causes, reactions, and troubleshooting actions.

Section 8 Additional Information

Draining and Calibration Procedures

Instructions for draining the chiller and calibrating sensors and transducers.

WARRANTY Information

Thermo Scientific ThermoFlex24000 Specifications

General IconGeneral
BrandThermo Scientific
ModelThermoFlex24000
CategoryChiller
LanguageEnglish