Thermo Scientific
ThermoFlex
TM
Recirculating Chillers
(Basic Controller)
Thermo Scientic Manual P/N U00933
Rev. 11/03/2017
Visit our Web site at:
http://www.thermofisher.com/tc
Product Service Information, Applications
Notes, SDS Forms, e-mail.
Voice Info: (800) 258-0830
Multilingual Quick
Start Guides
Multilingual Essential
Safety Instructions
Installation
Operation
Preventive
Maintenance
Troubleshooting

Table of Contents

Questions and Answers

  • L
    Linda HamptonAug 8, 2025
    How to troubleshoot a Thermo Scientific ThermoFlex5000 that will not start?
    • C
      Cassidy RyanAug 9, 2025
      If your Thermo Scientific Chiller won't start, begin by inspecting the electrical connections. If it's the first time you're using it, refer to the quick start instructions. Check the controller for any error codes. Also, make sure the optional GFCI breaker on the rear is in the up position. For ThermoFlex900 - 10000 chillers, ensure the circuit protector is in the on ( I ) position. Confirm that the supply voltage is connected and matches the chiller's nameplate rating ±10%. If there's no display or it shows 8888 on ThermoFlex900 - 10000, try recycling the circuit protector on the rear.
  • T
    Thomas BakerAug 28, 2025
    How to fix inadequate temperature control on a Thermo Scientific ThermoFlex5000 Chiller?
    • D
      Dr. Adam HortonAug 28, 2025
      To address inadequate temperature control in your Thermo Scientific Chiller, start by verifying the setpoint. If the chiller is over-cooling, recycle the power. Ensure the condenser/air filter is free of dust and debris, and confirm the chiller installation complies with site requirements. Check that the supply voltage matches the chiller's nameplate rating ±10%. For ThermoFlex900 - 5000 global voltage chillers, make sure the chiller is properly configured. If the temperature continues to rise, ensure your application's heat load does not exceed the rated specifications. Also, check for high thermal gradients and verify/adjust controller PID values.
  • S
    Shelly RuizNov 17, 2025
    What to do if my Thermo Scientific ThermoFlex5000 shuts down unexpectedly?
    • D
      Denise PerezNov 17, 2025
      If your Thermo Scientific Chiller shuts down, first ensure that wasn't accidentally pressed. Check that the optional GFCI breaker on the rear is in the up position and, for ThermoFlex900 - 10000 chillers, that the circuit protector is in the on ( I ) position. Examine the controller for error codes. Remember the chiller is designed to shut down if not properly primed. Confirm the supply voltage matches the chiller's nameplate rating ±10%, and then restart the chiller. If there is inadequate pump pressure, ensure any user installed in-line valves are in the desired position. Also, ensure the chiller’s process fluid outlet is connected to the application’s fluid inlet and not the application’s fluid outlet. All connections should be secure, using the proper sealant/lubricant for the fitting ...

Summary

Section 1 Safety

Safety Warnings

Details potential hazards and precautions to avoid injury or damage.

Section 3 Installation

Electrical Requirements

Details electrical service requirements, including voltage, frequency, and circuit protection.

Hard Wire Installation

Procedure for connecting the chiller directly to the electrical supply, requiring qualified personnel.

Plumbing Requirements

Guidelines for connecting process fluid lines, including types of connections and materials.

Process Fluid Requirements

Details requirements for process fluids, including approved types, warnings, and handling precautions.

Compatibility with Approved Fluids

Information on compatible fluids, their properties, and recommended usage.

Initial Filling

Steps for filling the reservoir and ensuring proper fluid levels.

Priming

Instructions for filling the chiller and application lines with process fluid.

Section 4 Operation

Basic Controller

Overview of the controller, its buttons, and functions for operating the chiller.

Setup

Initial setup procedures for configuring the chiller settings for first-time use.

Start Up

Step-by-step guide for powering up and initiating the chiller's operation.

Controller Loops

Explains how to navigate and use different operational loops like Setpoint, Setup, and Diagnostic.

Menu Tree

Visual representation of the controller's menu structure for accessing settings and loops.

Setpoint Loop (SP)

Procedure for displaying and adjusting the desired process fluid temperature setpoint.

Setup Loop (SEtuP)

Guide to adjusting controller settings, including scales, alarms, and optional features.

Section 5 Options;Accessories

Lockout;Tagout (LOTO)

Procedure for safely de-energizing the chiller system before maintenance.

Section 6 Preventive Maintenance

Diagnostic Loop

Explains how to view or reset operating times for various chiller components.

Testing the Alarm Features

Procedure for testing chiller alarms by adjusting setpoints and simulating conditions.

Section 7 Troubleshooting

Error Codes

Lists and explains various error codes displayed by the controller and their causes.

Checklist

A checklist for troubleshooting common chiller startup and operational problems.

Verifying;Adjusting the Controller PID Values (Tune Loop)

Procedure for verifying and adjusting controller PID values to resolve temperature control issues.

Section 8 Additional Information

Internal Fluid Temperature Sensor (rdt1) Calibration

Procedure for calibrating the internal fluid temperature sensor for accurate readings.

Process Fluid Pressure (P1) Transducer Calibration

Procedure for calibrating the process fluid pressure transducer for accurate measurements.

Optional Process Fluid Flow (FLo) Transducer Calibration

Procedure for calibrating the optional process fluid flow transducer.

Preface

Warranty

Details the warranty terms and conditions for Thermo Scientific ThermoFlex chillers.

Appendix B Voltage Configuration Instructions

Appendix C Analog I;0 and Remote Sensor

Analog Input Calibration

Procedure for calibrating the analog input signals for voltage or current.

Appendix D NC Serial Communications Protocol

WARRANTY

Thermo Scientific ThermoFlex5000 Specifications