Electrically Controlled Tankless Water Heater
Installa�on Guide, User Manual, and Warranty Informa�on
Electrically
Controlled
Instant Water
Heater
Elex Compact Series
Elex Comfort Series

Other manuals for ThermoFlow Elex 24

Questions and Answers

  • A
    Anthony MezaAug 17, 2025
    Why is my ThermoFlow Elex 24 heating, but the water is not hot enough?
    • J
      Jennifer BellAug 17, 2025
      There are several reasons why your ThermoFlow Water Heater might not be producing hot enough water: * The user temperature setting may be too low - try increasing it. * The flow rate might be too high; consider installing a flow regulator to reduce it. * If it’s a new installation, the wiring could be incorrect; have your electrician double-check it. * The voltage may be less than 380 volts for 3-Phase models or less than 220 volts for Single-Phase models. In this case, you may need to upgrade to a larger input heater. * You might be mixing too much cold water; adjust your faucet's anti-scald feature to reduce cold water mixing.
  • M
    Mary BowenAug 19, 2025
    What to do if my ThermoFlow Water Heater display lights up but shows no temperature and isn't heating?
    • D
      Donald WardAug 19, 2025
      If your ThermoFlow Water Heater's display lights up but shows no temperature and isn't heating, it could be due to several reasons: * The flow rate might be too low. Your water heater needs a flow rate of approximately 2.2L/min / 2.5L/min to activate. Increase the flow rate or check the filter mat inside the inlet connector. * Air bubbles might be trapped. Turn on the unit and open the hot water tap for about 20 seconds to purge them. * The flow sensor might be blocked. Try uninstalling and cleaning it. * The connector between the flow sensor and the main board might be loose. Unplug and replug it.
  • B
    benjaminhernandezAug 22, 2025
    How to fix a ThermoFlow Elex 24 when it's not heating and the display is off?
    • A
      Amber WaltersAug 22, 2025
      If your ThermoFlow Water Heater isn't heating and the digital display is off, it could be due to no power or incorrect wiring. First, ensure the breakers at your main electrical panel are turned ON. It's also possible you have a faulty breaker or that the unit is wired incorrectly. You may need to have an electrician check the wiring.
  • S
    Stephanie MurphyAug 26, 2025
    What to do if ThermoFlow Elex 24 Water Heater is not heating but the display is on?
    • D
      danielwallerAug 26, 2025
      If your ThermoFlow Water Heater's digital display is on, but the water isn't heating, the issue might be: * Flow rate is too low / water pressure is too low. Your water heater needs approximately 0.6 GPM (2.5 LPM) to activate. Increase the flow rate or check the filter mat inside the inlet connector. * The air bubbles in the water heater have not been purged out. Make sure the breakers at the main electrical panel are ON, turn on the unit, and open the hot water tap for about 20 seconds.
  • W
    William WalkerAug 27, 2025
    How to troubleshoot ThermoFlow Elex 24 when the digital display doesn't light up?
    • U
      ucookAug 27, 2025
      If your ThermoFlow Water Heater's digital display isn't lighting up and the water isn't heating, first, ensure the breakers at the main electrical panel are ON. You might have a faulty breaker or the unit could be wired incorrectly.
  • C
    Carrie HurleyAug 30, 2025
    Why is the water temperature at the faucet different from my ThermoFlow Elex 24 setting?
    • C
      Cindy GallagherAug 31, 2025
      The water temperature at the faucet differing from your ThermoFlow Water Heater setting can be due to a few reasons: * Your faucet might have an anti-scald feature or tempering valve that mixes cold water, even on full hot. Adjust the valve to reduce cold water mixing. You can compensate for this by increasing the setting on your water heater if you need/want hotter water. * Heat loss can occur due to long pipe runs, especially if the pipes are cold. You can compensate for this by increasing the setting on your water heater if you need/want hotter water. * If the water temperature at the faucet is too hot, check if the flow is too little or the set point temperature is too high.
  • J
    Judy LopezSep 2, 2025
    How to fix low flow rate on ThermoFlow Elex 24 Water Heater?
    • C
      Clayton PayneSep 2, 2025
      If you're experiencing a low flow rate with your ThermoFlow Water Heater, the filter mat inside the inlet connector or the pipe might be blocked. Check and clean the filter mat inside the inlet connector to resolve this issue.
  • A
    Amanda MaloneSep 7, 2025
    Why is the water temperature different from my ThermoFlow Water Heater setting?
    • R
      Ronald EllisSep 7, 2025
      The water temperature at the faucet might differ from your ThermoFlow Water Heater setting due to: * An Anti-Scald pressure/balancing valve or tempering valve. These may automatically mix cold water, even on full hot. Adjust these devices to reduce cold water mixing. You can also increase the water heater setting to compensate. * Thermal loss due to a long pipe run. Heat loss can occur as hot water travels, especially over long distances or through cold pipes. Increase the water heater setting to compensate. * Water temperature at the faucet is too hot. Check your flow for too little flow, set point temperature is too high.
  • S
    Shannon WilkinsSep 12, 2025
    How to increase the flow rate on my ThermoFlow Elex 24 Water Heater?
    • S
      Scott ZimmermanSep 12, 2025
      A low flow rate in your ThermoFlow Water Heater may be due to a blockage. Check and clean the filter mat inside the inlet connector. Also, inspect the pipe for any blockages.
  • C
    Craig SmithSep 13, 2025
    What does error code 'E2' mean on my ThermoFlow Elex 24 Water Heater?
    • A
      Amanda CookeSep 13, 2025
      If your ThermoFlow Water Heater's LCD display shows “E2”, it indicates an internal part failure. Please call for your local service.

Summary

Mounting Instructions

Water Supply Connection

Details how to connect the appliance to the water supply.

Electrical Installation

Covers electrical connection requirements and safety measures.

Installation Tools and Preparation

Pre-Installation Steps

Key steps and safety considerations before starting the installation.

Commissioning the Water Heater

Technical Specifications Overview

Technical Specifications (Single-Phase)

Technical Specifications (3-Phase Compact)

Technical Specifications (3-Phase Comfort)

Technical Specifications (Single-Phase Comfort)

User Manual

Troubleshooting Guide

First Aid for Issues

Immediate steps to take for common operational problems.

Troubleshooting (Continuation)

ThermoFlow Elex 24 Specifications

General IconGeneral
Power24 kW
Voltage400 V
Phase3
Temperature Range30-60 °C
Maximum Flow Rate12 l/min

Related product manuals