Material Safety
Data Sheet
Date Revised: 7/2/91
PRODUCT IDENTIFICATION
Trade Name(s): CERAFIBER
Generic Name: REFRACTORY CERAMIC FIBER INSULATION CAS #: 65997-17-3
Chemical Name: ALUMINA SILICA Formula: MIXTURE
Manufacturer: Thermal Ceramics Telephone: (404) 796-4200
Address: P.0. BOX 923, 2102 Old Savannah Road
City: Augusta State: Georgia Zip: 30903
PRODUCT INGREDIENTS
INGREDIENT NAME CAS NUMBER % PEL and TLV (except as noted)
REFRACTORY CERAMIC FIBER 65997-17-3 100 1 FIBER/CC EXPOSURE GUIDELINE
5mg/M
3
- NUISANCE RESPIRABLE - OSHA
10mg/M
3
- NUISANCE TOTAL - ACGIH
CRYSTALLINE SILICA (CRISTOBALITE) WILL FORM
"AFTER SERVICE" AT TEMPERATURES >1000°C.
14464-46-1 >20
0.05 mg/M
3
- OSHA Respirable Dust
PHYSICAL DATA
Appearance and Odor: WHITE FIBER-NO ODOR.
Boiling Point: NA Evaporation Rate (NA = 1): NA
Vapor Pressure: NA Specific Gravity (water = 1 ): 2.6
Water Solubility (%): NIL Melting Point: >3000°F
Vapor Density (Air= l): NA % Volatile by Volume: 0
FIRE AND EXPLOSION DATA
Flash Point (Method): NONFLAMMABLE
NFPA Flammable/Combustible Liquid Classification: NA
Flammable Limits: LEL: NA % UEL: NA %
Auto-Ignition Temperature: NA
HEALTH HAZARDS
Summary/Risks
Summary: EXPOSURE TO DUST FROM THIS PRODUCT SHOULD BE MINIMIZED. ANIMAL INHALATION AND ARTIFICIAL
IMPLANTATION STUDIES HAVE REPORTED THE DEVELOPMENT OF TUMORS. BASED ON PRELIMINARY RESULTS,
A NOTICE OF SUBSTANTIAL RISK HAS BEEN FILED WITH THE EPA ACCORDING TO SECTION 8(e) OF THE TOXIC
SUBSTANCES CONTROL ACT. BASED ON ANIMAL STUDIES, IARC HAS CLASSIFIED RCF AS POSSIBLY
CARCINOGENIC FOR HUMANS (2B). DATA FROM HUMAN EPIDEMIOLOGICAL STUDIES IS INSUFFICIENT. THIS
SUBSTANCE OR MIXTURE HAS NOT BEEN CLASSIFIED A CARCINOGEN BY NTP OR OSHA.
Medical conditions which may be aggravated: AS WITH ANY DUST, PRE-EXISTING UPPER RESPIRATORY AND LUNG
DISEASES MAY BE AGGRAVATED.
Target Organ(s): LUNGS, SKIN AND EYES .
Acute Health Effects: PRODUCT IS A MECHANICAL IRRITANT TO SKIN, EYES AND UPPER RESPIRATORY SYSTEM.
Chronic Health Effects: EXCESSIVE EXPOSURE TO RCF DUSTS AND AFTER SERVICE FIBERS MAY CAUSE LUNG
DAMAGE (FIBROSIS). IARC STATES THERE IS SUFFICIENT EVIDENCE IN ANIMALS AND LIMITED EVIDENCE IN
HUMANS TO CLASSIFY CRYSTALLINE SILICA AS A PROBABLE CARCINOGEN (2A) AND RCF AS A POSSIBLE
CARCINOGEN (2B).
Primary Entry Route(s): INHALATION, SKIN AND EYE CONTACT.
Signs/Symptoms of Overexposure
Inhalation: IRRITATION OR SORENESS IN THROAT & NOSE. IN EXTREME EXPOSURES SOME CONGESTION MAY
OCCUR.
Skin Contact: TEMPORARY IRRITATION OR RASH.
Skin Absorption: NA
Ingestion: NOT HAZARDOUS WHEN INGESTED. MAY CAUSE TEMPORARY IRRITATION TO GI TRACT.