7
EN
Installation manual: Installation location
Example for suspended device
230 V switch board
16 A circuit breaker
and30mAdifferential.
Permanent connection (24/7).
Phase
Earth
Neutral
Plastic
dielectric
union
Hot water connection
Dielectric
union
Hot
water
outlet
Safety valve
Cold
water
inlet
Thread seal tape
to be applied in
the direction of
the screw thread
Safety valve
Cold water connection
MANDATORY MANDATORY
3. Electrical and hydraulic connection