EasyManua.ls Logo

THORLABS GVS012 - User Manual

THORLABS GVS012
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
HA0220T
GVS011 and GVS012
GVS111 and GVS112
GVS211 and GVS212
GVS311 and GVS312
GVS411 and GVS412
Large Beam Diameter
Scanning Galvo Systems
User Guide
Original Instructions

Questions and Answers

  • R
    rebecca76Aug 8, 2025
    How to fix THORLABS GVS012 Scanner motor not responding?
    • T
      Tara ProctorAug 8, 2025
      If the THORLABS Scanner motor isn't responding, ensure power is correctly applied to the board. Also, check for faulty or improperly connected cables. Try resetting the device to clear any faults. Finally, verify the device is not disabled by checking the jumper settings.
  • M
    moorekennethAug 11, 2025
    Why is my THORLABS GVS012 unstable?
    • B
      Benjamin SolomonAug 11, 2025
      Scanner instability can occur if the driver board is incorrectly tuned to the motor, so re-tune it. Ensure the driver board is connected to the correct motor. Check and reset any tampered potentiometers. Avoid driving the motor with excessive amplitude and frequency.
  • R
    Randy RamseyAug 16, 2025
    What to do if THORLABS GVS012 galvo periodically becomes unstable?
    • K
      kcurtisAug 17, 2025
      If the THORLABS Scanner galvo periodically becomes unstable, it may be due to an incorrectly tuned galvo driver card. In this case, re-tune the galvo driver card. Also, ensure the error signal remains within acceptable limits, as exceeding the maximum error signal value can cause instability.
  • M
    Morgan HernandezAug 20, 2025
    Why does THORLABS Scanner position signal overshoot and grow over time?
    • R
      Robert Brown MDAug 20, 2025
      An overshoot in the position signal that grows over time in your THORLABS Scanner may be due to a power supply that cannot deliver enough current for the intended application. Choose a power supply that can deliver adequate current.
  • T
    tracy35Aug 25, 2025
    What causes THORLABS GVS012 mirror to shoot off to one side?
    • R
      Robert ColemanAug 25, 2025
      If the THORLABS Scanner mirror periodically shoots off to one side and then stops, it could be due to the position sensing circuitry not functioning correctly. Check and repair the position sensing circuitry. Alternatively, the motor cable may be incorrectly wired; inspect and rewire it properly.
  • P
    parkermartinezAug 28, 2025
    How to stop oscillation in THORLABS Scanner galvo motor current?
    • Q
      qsandersAug 29, 2025
      Oscillation in the THORLABS Scanner galvo motor current can be caused by crosstalk between the position sensing circuitry and the motor drive current. Reposition the motor drive cable. Also, use separate shielded cables for the position sensing and motor drive signals.
  • S
    Stacy CunninghamSep 2, 2025
    Why is there cross talk between axes in my THORLABS GVS012 Scanner?
    • J
      Justin HansonSep 2, 2025
      Cross talk between axes can occur if both motors run off the same power supply, which cannot deliver peak currents. Choose a different power supply with sufficient peak drive current capability to test.

THORLABS GVS012 Specifications

General IconGeneral
Input Voltage±15 V
Wavelength Range400 - 700 nm
Clear Aperture12 mm
Optical Aperture12 mm
TypeGalvanometer
Max Scan Angle±10 degrees
Maximum Scan Angle (Optical)±20 degrees