2007.03.07 Flow2 stairlift Tab 06: Systematic fault finding
www.ThyssenKruppAccessibility.nl 19
Error messages
Possible
solution
- Switch the lift off and on.
- If the error keeps appearing, try to restore a recent backup of the standard
factory rail data from the flash card.
Reset Switch off and on.
Modes 0, 2
Error code E04
Type of error System error / control error
Error message Table-data corrupted
Description This fault indicates that the stored table data is corrupt. This message mainly
appears when, during switching on, the parameter settings are read out.
Because the lift cannot operate without correct rail data, a standard table is
created where the speed is set to 30% and the swivel angle to 0º.
Priority Highest
Possible
solution
- Switch the lift off and on.
- If the error keeps appearing, try to restore a recent backup of the standard
factory rail data from the flash card.
Reset Switch off and on.
Modes 0, 2
Error code E05
Type of error System error
Error message Safety MCU not responding
Description This error indicates that safety processor does not answer requests from the
main processor.
Priority Highest