INSTALLATION
104
NG10 - Manual - 04 - 2022
The Thybus link must be carried out by means category 5 shielded cable with RJ45 connectors.
The maximum length of the Pro-N device - module link is:
2 m for MRI module (max one module)
20 m for MMOS-4 module (max one MMI module)
THYBUS OUTPUTTHYBUS INTPUT
MRI
BINARY INPUTS
OUTPUT RELAYS
52
IN1
51
50
IN2
49
48
IN3
47
IN4
IN5
43
42
IN6
41
40
IN7
35
34
33
32
31
30
3
IN8
5
6
7
K1
11
12
13
K2
16
15
14
K3
22
21
20
K4
THYBUS OUTPUTTHYBUS INTPUT
MID16
BINARY INPUTS
52
IN1
51
50
IN2
49
48
IN3
47
IN4
IN5
43
42
IN6
41
40
IN7
35
34
33
32
31
30
3
IN8
5
IN9
6
7
IN10
8
11
IN11
12
IN12
IN13
13
14
IN14
15
16
IN15
20
21
22
23
24
25
IN16
Pro_N
E1
THYBUS
3436 35
303233
31
28
29
434445
39
40
42 41
38
37
5254 53
48
5051
49
46
47
MODULO INGRESSI REMOTI
INPUTOUTPUT
ON
RUN
BUS
1 2 3
4 5
6
7
8
9
18
17
16
15
1413
121110 212019
252322
24
27
26
MID-16
3436 35
303233
31
28
29
434445
39
40
42 41
38
37
5254 53
48
5051
49
46
47
1 2 3
4
5
6
7
8
9
18
17
16
15
1413
121110 212019
252322
24
27
26
MODULO INGRESSI REMOTI
INPUTOUTPUT
ON
RUN
BUS
MID-16
1 2 3
4 5
6
7
8
9
18
17
16
15
1413
121110 212019
252322
24
27
26
3436 35
303233
31
28
29
434445
39
40
42 41
38
37
5254 53
48
5051
49
46
47
MID8
MODULO INGRESSI REMOTI
INPUTOUTPUT
ON
RUN
BUS
OUTPUT
ON
BUS
RUN
1
2
3
4
5
MODULO 4 RELE’ + 8 INGRESSI DIGITALI
4 RELAYS + 8 BINARY INPUTS MODULE
INPUT
MRI
PT1 MPT1
3436 35
303233
31
28
29
434445
39
40
42 41
38
37
5254 53
48
5051
49
46
47
1 2 3
4
5
6
7
8
9
18
17
16
15
1413
121110 212019
252322
24
27
26
OUTPUT
MPT
ON
BUS
RUN
MODULO PT100
PT100 MODULE
INPUT
PT2 MPT2 PT3 MPT3 PT4 MPT4
PT8 MPT8 PT7 MPT7 PT6 MPT6 PT5 MPT5
PUTNI SUBYHT TUPTUO SUBYHT
MPT
8
T1
PT1 PT8
MPT1 MPT8
PT7
MPT7
PT6
MPT6
PT5
MPT5
PT2
MPT2
PT3
MPT3
PT4
MPT4
T8
7
6
T7
T6
T5
11
T2
12
13
15
T3
16
17
20
T4
21
22
49
48
47
44
43
42
40
39
38
35
34
33
THYBUS INPUT THYBUS OUTPUT
MCI
47
48
11
NC
MIS-1
-
+
12
13
# / ∩
14
NC
MIS-2
-
+
15
16
# / ∩
20
NC
MIS-3
-
+
21
22
# / ∩
23
NC
MIS-4
-
+
24
25
# / ∩
U
AUX
3436 35
303233
31
28
29
434445
39
40
42 41
38
37
5254 53
48
5051
49
46
47
1 2 3
4
5
6
7
8
9
18
17
16
15
1413
121110 212019
252322
24
27
26
OUTPUT
MCI
ON
BUS
RUN
1
2
3
4
5
MODULO CORRENTE IMPRESSA
CURRENT LOOP OUTPUT MODULE
INPUT
Thybus

Table of Contents