EasyManuals Logo

Thytronic NVA100X User Manual

Thytronic NVA100X
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
15
NVA100X - Getting started - 01 - 2018
NVA100X_menuread1a.ai
PROTECTIONS
27 >>
Start U< OFF
Trip U< OFF
BLK1 U< OFF
Start U<< OFF
Trip U<< OFF
BLK1 U<< OFF
27V1 >>
Start U1< OFF
Trip U1< OFF
BLK1 U1< OFF
37 >>
Start I< OFF
Trip I< OFF
BLK1 I< OFF
37P >>
Start P1< OFF
Trip P1< OFF
BLK1 P1< OFF
Start P2< OFF
Trip P2< OFF
BLK1 P1< OFF
Start IE> OFF
Trip IE> OFF
CLP IE> OFF
BLK1 IE> OFF
BLK2IN IE> OFF
BLK4IN IE> OFF
Start IE>> OFF
Trip IE>> OFF
CLP IE>> OFF
BLK1 IE>> OFF
BLK2IN IE>> OFF
BLK4IN IE>> OFF
Start IE>>> OFF
Trip IE>>> OFF
CLP IE>>> OFF
BLK1 IE>>> OFF
BLK2IN IE>>> OFF
BLK4IN IE>>> OFF
50N/51N-87NHIZ >>
Start IEC> OFF
Trip IEC> OFF
CLP IEC> OFF
BLK1 IEC> OFF
BLK2IN IEC> OFF
BLK4IN IEC> OFF
Start IEC>> OFF
Trip IEC>> OFF
CLP IEC>> OFF
BLK1 IEC>> OFF
BLK2IN IEC>> OFF
BLK4IN IEC>> OFF
Start IEC>>> OFF
Trip IEC>>> OFF
CLP IEC>>> OFF
BLK1 IEC>>> OFF
BLK2IN IEC>>> OFF
BLK4IN IEC>>> OFF
50N(C)/51N(C) >>
37Q >>
Start P1< OFF
Trip P1< OFF
BLK1 P1< OFF
Start P2< OFF
Trip P2< OFF
BLK1 P1< OFF
32P >>
Start P1> OFF
Trip P1> OFF
BLK1 P1> OFF
Start P2> OFF
Trip P2> OFF
BLK1 P2> OFF
32Q >>
Start Q1> OFF
Trip Q1> OFF
BLK1 Q1> OFF
Start Q2> OFF
Trip Q2> OFF
BLK1 Q2> OFF
49MG >>
Alarm DThAL OFF
BLK1 DThAL OFF
BLK2IN DThAL OFF
Trip DTh> OFF
BLK1 DTh> OFF
BLK2IN DTh> OFF
Alarm DThAL1 OFF
BLK1 DThAL1 OFF
BLK2IN DThAL1 OFF
BLK4IN DThAL1 OFF
Alarm DThAL2 OFF
BLK1 DThAL2 OFF
BLK2IN DThAL2 OFF
BLK2IN DThAL2 OFF
BLK4IN DThAL2 OFF
Trip DTh> OFF
BLK1 DTh> OFF
BLK2IN DTh> OFF
BLK4IN DTh> OFF
CLP DTh OFF
49LT >>
79 >>
ActiveMode 79 OFF
Run 79 OFF
CycleState 79 Rest
Residual-time 79
0 s
LastEvent 79
No events
EnableState 79 OFF
Start(U/f)AL OFF
Trip (U/f)AL OFF
BLK1 (U/f)AL OFF
Start(U/f)> OFF
Trip (U/f)> OFF
BLK1 (U/f)> OFF
Start(U/f)>> OFF
Trip (U/f)>> OFF
BLK1 (U/f)>> OFF
24 >>
Synchro Avv OFF
Synchro ControlOFF
Synchro Trip OFF
Synchro diagnostic
State V1-SYNC OFF
State V4-SYNC OFF
State f1-RANGE OFF
State f4-RANGE OFF
State V1>SYNC OFF
State V4>SYNC OFF
State V1<SYNC OFF
State V4<SYNC OFF
State df-net OFF
State df-SYNC OFF
State dphi-SYNCOFF
25 >>
I2/I1 >>
Start I21> OFF
Trip I21> OFF
BLK1 I21> OFF
CLP I21> OFF
46M >>
Start I2> OFF
Trip I2> OFF
CLP I2> OFF
BLK1 I2> OFF
BLK2IN I2> OFF
Start I2>> OFF
Trip I2>> OFF
CLP I2>> OFF
BLK1 I2>> OFF
BLK2IN I2>> OFF
Start I> OFF
Trip I> OFF
CLP I> OFF
BLK1 I> OFF
BLK2IN I> OFF
BLK4IN I> OFF
Start I>> OFF
Trip I>> OFF
CLP I>> OFF
BLK1 I>> OFF
BLK2IN I>> OFF
BLK4IN I>> OFF
Start I>>> OFF
Trip I>>> OFF
CLP I>>> OFF
BLK1 I>>> OFF
BLK2IN I>>> OFF
BLK4IN I>>> OFF
50/51 >>
PROCEED READ MENU’
Start I2AL> OFF
Trip I2AL> OFF
BLK1 I2AL> OFF
Start I2>> OFF
Trip I2>> OFF
BLK1 I2>> OFF
46G >>
47 >>
Start US1< OFF
Start US> OFF
Trip 47 OFF
BLK1 47 OFF
55 >>
Start CPhi1< OFF
Trip CPhi1< OFF
BLK1 CPhi1< OFF
Start CPhi2< OFF
Trip CPhi2< OFF
BLK1 CPhi2< OFF
46LT >>
Start I2> OFF
Trip I2> OFF
CLP I2> OFF
BLK1 I2> OFF
BLK2IN I2> OFF
Start I2>> OFF
Trip I2>> OFF
CLP I2>> OFF
BLK1 I2>> OFF
BLK2IN I2>> OFF