8. ERROR CODES
Error
Code No.
Description
Err 1 Time value error
Err 2 Date value error
Err 3
Logic error. LO limit is higher than HI limit
(and HI is not = 0)
Err 4 Not sense the loadcell signal
Err 5 Exceed maximum power on zero range
Err 6 Exceed maximum manual zero range
Err 7 Tare operation error
Err 8 Offset out of range / unstable during power on
Err 9
ERROR IN PERCENTAGE FUNCTION. INPUT VALUE
= 0 or less than 50e
--oL-- Overload (Gross weight is more than Max plus 9d)
UndEr
Under load (Gross weight is less than minus 20d)