IMPORTANT NOTICE
Electricity will be supplied to the Tigo TS4-A output cables immediately when connected to a PV module
exposed to sunlight. Use care when handling.
注意事
当连接的组件暴露在阳光下时电力将会从Tigo TS4-A输出端输出。请小心处理。
ATTENTION!
Une fois connecté au panneau photovoltaïque exposé au soleil, les boitiers Tigo TS4-A laisseront passer le
courant. Soyez vigilant.
WICHTIGER HINWEIS
Bei Verbindung der Tigo TS4-A mit einem aktiven PV-modul steht der Ausgang unmittelbar unter Spannung.
Bitte Vorsicht im Umgang.
AVVISO IMPORTANTE
Prestare la massima attenzione: i cavi di uscita dei Tigo TS4-A sono già alimentati con energia elettrica quando
vengono collegati a un modulo fotovoltaico esposto alla luce del sole.
안전을 주의사항
햇빛에 노출된 태양전 모듈에 연결하면 Tigo TS4-A 케이블에 전기가 흐르게 됩니다. 취급시 주의하십시.
重要事
日射下の太陽光モジュールを接続すると同時に、タイTS4-Aの出力 ケーブルにも電気が流れますので、取扱いには十分
ご注意ください。
¡PRECAUCION!
Al momento de conectar los cabels de salida los Tigo TS4-A a un módulo fotovoltaico expuesto al sol, se inicia
la corriente eléctrica. Tenga cuidado en su manejo.
Maximum power: 700W
Maximum voltage: 80V
DC
Maximum current: 15A
DC
Maximum system voltage 1000V / 1500V
Class II double insulation
High Voltage
DANGER
Use ANSI/NFPA 70 wiring methods.
Modules must not be installed in readily accessible locations. (Canada only)
Connectors from different manufacturers cannot be mated with each other.
002-00071-00 08/18/2021 Rev. A2
TS4-A-O: Module-level Optimization
The TS4-A-O is the advanced add-on solution that brings smart
module functionality to standard PV modules, including
optimization, rapid shutdown, and module-level monitoring.
Photovoltaic Rapid Shutdown Equipment NEC 690.12 and C22.1-2015 Rule 64-218
The Tigo Access Point (TAP) is a PVRSE device that provides a keep-alive signal to
the TS4 (attenuator) device via wireless communications.
The Tigo Access Point (TAP) shall be powered from the same power as the RSI
(Rapid Shutdown Initiator) circuit and tied to the shutdown of the inverter.
1
3
2
4
PV Module -
String -
String +
PV Module +
*Collect TS4 bar code for
system mapping to
enable monitoring and
safety features
4 - 123A
TS4-A-O
4-1234T
41 32

Other manuals for Tigo TS4-A-O

Question and Answer IconNeed help?

Do you have a question about the Tigo TS4-A-O and is the answer not in the manual?

Tigo TS4-A-O Specifications

General IconGeneral
Maximum Input Voltage60 V
Maximum Output Current15 A
Operating Temperature Range-40°C to +85°C
Maximum Input Current15 A
Maximum Output Voltage80 V
IP RatingIP68
Efficiency99.5%
FunctionOptimization
Protection FeaturesOver-temperature, over-voltage
TypeMLPE (Module Level Power Electronics)