Connecting the hob to the mains power supply
The power supply should be connected in compliance with the relevant standard, or a single-
pole circuit breaker. The appliance has a large power rating and must be connected to
electricity by a Qualified Electrician.
Notes:
1. If the cable is damaged or needs replacing, this should be done by an after-sales technician
using the proper tools, so as to avoid any accidents.
2. If the appliance is being connected directly to the mains supply, an omni polar circuit breaker
must be installed with a minimum gap of 3mm between the contacts.
3. The installer must ensure that the correct electrical connection has been made and that it
complies with safety regulations.
4. The cable must not be bent or compressed.
5. The cable must be checked regularly and only replaced by qualified technician.
Cautions
1. The hob must be installed by qualified personnel or technicians. Please never conduct
the operation by yourself.
2. The electric hob shall not be mounted to cooling equipment, dishwashers and rotary dryers.
3. The electric hob shall be installed such that better heat radiation can be ensured to enhance
its reliability.
4. The wall and induced heating zone above the work surface shall withstand heat.
5. To avoid any damage, the sandwich layer and adhesive must be heat resistant.
6. This electric hob can be connected only to a supply with system impedance no more than
0.427 ohm. In case necessary, please consult your supply authority for system impedance
information.