1
1. General Information
These instructions should be read carefully and retained for further
reference and maintenance.
2. Safety
• Before installation or maintenance, ensure the mains supply to
the PIR sensor is switched off and the circuit supply fuses
are removed or the circuit breaker turned off.
• It is recommended that a qualified electrician is consulted or used
for the installation of this PIR sensor and install in accordance
with the current IEE wiring and Building Regulations.
• Check that the total load on the circuit including when this
PIR sensor is fitted does not exceed the rating of the circuit cable,
fuse or circuit breaker.
3. Technical Specifications
• 230V AC 50 Hz
• Motion Detection Range: Up to 6 metres diameter (3m Radius)
at a 2.5m mounting height
• This PIR sensor is of class II construction and must not be earthed
• Detection Angle: 360°
• Maximum Switching Load; 2400W Halogen, 500W Fluorescent,
150W CFL/Low Energy,
LED lamps <10W Lamps, max 100W.
LED lamps >10W <32W, max 50W.
75W Fan
• Time ON Adjustment: 5 seconds to 18 minutes.
• Dusk Level Adjustment: Day and Night or Night time only operation.
• IP44 Rated suitable for restricted internal applications
• CE Approved
• Manual Override
• Multiple PIR Sensor Switching: A maximum of 8 SLFM360L PIR sensors
can be wired in parallel, to enable any
detector to turn ON all the lights connected.
The total load must not exceed the lamp
rating of a single SLFM360L unit.