Getting started...
EN
26
In more detail...
Troubleshooting
Troubleshooting
Suspected malfunctions are often due to causes that the user can x
themselves. Therefore check the product using this section. In most cases the
problem can be solved quickly.
WARNING! Only perform the steps described within these
instructions! All further inspection, maintenance and repair work must
be performed by an authorised service centre or a similarly qualied
specialist if you cannot solve the problem yourself!
Problem Possible cause Solution
1. Product does
not start
1.1. Not connected to power
supply
1.1. Connect to power supply
1.2. Power cord or plug is
defective
1.2. Check by a specialist
electrician
1.3. Other electrical defect
to the product
1.3. Check by a specialist
electrician
1.4. Overloaded product 1.4. Disconnect the product
and remove cause of
overload
2. Product does
not reach
operating
pressure
2.1. Air vents are blocked 2.1. Clean the air vents
2.2. System is not airtight 2.2. Check and tighten all
connections / valves
2.3. Power source
(e. g. generator) has
too low voltage
2.3. Connect to another power
source
3. Unsatisfactory
result
3.1. System is not airtight 3.1. Check and tighten all
connections / valves
3.2. Insufcient pressure set
on the pressure gauge
3.2. Increase set pressure
according to technical
specications
3.3. Obstructed air vents 3.3. Clean air vents
3.4. Damaged pressure
gauge
3.4. Have the pressure gauge
replaced by a specialist
3.5. Inatable item is leaking 3.5. Repair the item before
inating again
4. Excessive
vibration /
noise
4.1. Bolts / nuts are loose 4.1. Tighten bolts / nuts
4.2. System is not airtight 4.2. Check and tighten all
connections / valve
4.3. Damaged motor 4.3. Have the product
checked by a specialist
4/19/17 4:36 PM