TM INDUCTION HEATING
9
ET 2.0 |
TIME MODE
Time Mode should only be used in production areas where the
workpiece to be heated is always of the same specications. To
determine the settings for Time Mode, the operator must heat the
part on Temperature Mode rst. During the heating cycle measure the
time using a stopwatch. The measured time can now be used as input
for Time Mode. When heating an object using Time Mode, the heating
cycle must be checked using an external temperature meter.
When the operator switches the heater on, the display will show
110°C (230°F). Press the Time Mode-button and the LED display will
show 00.00. Select the preferred time duration and press the button
labeled START/STOP to start the heating process. The LED display will
now show the time remaining.
Once the selected time duration has passed the heating cycle will automatically stop, an acoustic
signal can be heard, and the LED display will ash. Press the START/STOP-button to stop the
acoustic signal. Remove the workpiece from the induction heater. During the heating cycle, the
progress can be stopped at any moment by pressing the START/STOP-button.
Our standard temperature sensors are suitable for operation up to a maximum
temperature of 240°C (464°F). The connection between magnet and
temperature sensor will break above the maximum temperature.
MAINTENANCE5.
` Store in a dry, frost-proof area, free from humidity.
` Keep clean with a soft, dry cloth.
` Keep the touchpad clean for optimal visibility of the user interface.
` Keep the contact parts of the heater core poles greased. Grease regularly with an acid-free
grease for optimal contact and to avoid corrosion (in the case of heaters with a pivoting
yoke, also grease the vertical pin regularly).
` CRITICAL SPARE PART - Magnetic temperature sensor. Always use original spare parts, we
can not guarantee a proper functioning using other parts.
Proper maintenance and handling practices are critical. Failure to follow
installation and maintenance instructions can result in equipment failure,
creating a risk of serious bodily harm.