7 The rotating axis of the laser is directly over the center of the front oor mount leg in its
stored position. Therefore the beam will rotate forward of the control point when the laser
is rotated on the front oor mount leg.
The Off-set however is constant (59mm) from the rotation axis to the beam, so marking a
control point 59mm behind the actual control point will make set-up easy and accurate.