22
TF21/44R/T
U4
DL1
DL2
SP2
SW1
RT1
M7
SP1
M8
JP3
JP2 JP2
M12 M11 M10 M9
T
M5
M3
M4
M2 M1
230V ~ 50Hz
M 230Vac
12
3
4
BLUE
BLUE
BLUE
BROWN
BROWN
WHITE
YELLOW
A A A A A
C C
N.4
N.3 N.2 N.1
C C C
INSTALLATION AND USE INSTRUCTIONS
5- INSTALLATION
BLACK
BROWN
BLACK
BROWN
BLACK
BROWN
BLACK
BROWN
Remote control
programming
push-button
IT IS FORBIDDEN TO PERFORM THE CONNECTION TO THE
EARTHING PLANT OF THE DEVICES EQUIPPED WITH DOUBLE
INSULATION.
Heated rain
sensor
Wind
sensor
Brightness (sun)
sensor
(A=OPEN C=CLOSE)
General
control
Local control
(BLUE) GREY
(BLUE) GREY
(BLUE) GREY
(BLUE) GREY
Wiring diagram Mod. TF44
VER.1.0
REV.07.04