Questions and Answers

  • K
    Kelly GeorgeAug 18, 2025
    How to troubleshoot no electrical power in my Tornado 98250?
    • B
      Brian LopezAug 18, 2025
      If your Tornado Floor Machine has no electrical power, it could be due to a defective power cord, which should be replaced. Alternatively, the circuit breaker might be off, or a fuse blown. In this case, turn the circuit breaker on or replace the fuse, and unplug any other equipment using the same circuit.
  • J
    James RiggsAug 23, 2025
    Why does my Tornado 98250 have intermittent power?
    • J
      josephmarshAug 23, 2025
      If the switch is on but the motor(s) of your Tornado Floor Machine have intermittent power, the issue might stem from a faulty electrical cable (repair or replace it), defective switches (replace them), or a loose terminal (replace it).
  • C
    colleenandradeAug 26, 2025
    What to do if my Tornado 98250 pump motor runs but no spray?
    • S
      Steve FriedmanAug 26, 2025
      If the pump motor is running on your Tornado Floor Machine but there's no spray through the jets, the issue could be a clogged or faulty solution control valve (check the intake and remove any lint or foreign material), a clogged or faulty quick disconnect on the housing (depress the plunger on the solution hose against the inside wall of the solution tank to check for flow, and inspect the quick disconnect for obstructions), a punctured pump diaphragm (replace it with a diaphragm repair kit), or clogged jets (clean the jets on the wand or tool).
  • T
    Tina Hogan MDAug 28, 2025
    Why is the pump pressure low on my Tornado Floor Machine?
    • D
      Destiny ShafferAug 28, 2025
      If your Tornado Floor Machine has low pump pressure, check the screens on the strainer in the solution tank for clogs; if clogged, unscrew the strainer and remove any lint or foreign material. Also, inspect the pump diaphragm for punctures, and replace it with a diaphragm repair kit if needed. Finally, the pump may not be primed; plug the priming hose into the solution connection and place the end in the solution tank, then run the pump for 4 minutes.
  • L
    Logan MontgomeryAug 30, 2025
    Why does my Tornado 98250 Floor Machine have no vacuum and exhaust?
    • J
      Jonathan SchultzAug 30, 2025
      If the motor is running on your Tornado Floor Machine, but there is no vacuum and no exhaust from the blow-port, the vacuum motor might be faulty and require replacement. Alternatively, the water shutoff may be closed, in which case you should clean the water shutoff screen.
  • R
    Rose BellSep 2, 2025
    How to fix uneven spray from my Tornado 98250 jet?
    • K
      Kristopher JohnsonSep 2, 2025
      If your Tornado Floor Machine has an uneven spray from the jet, or the spray is weak, the strainer in the solution tank may be clogged. Unscrew the strainer and remove any lint or foreign material from the screen. Alternatively, the jet itself might be clogged; remove and clean it.
  • M
    marcia33Sep 4, 2025
    Why does the pump pressure vary on my Tornado 98250 Floor Machine?
    • A
      Aaron HarrisSep 5, 2025
      If the pump pressure varies on your Tornado Floor Machine, the carbon brushes might be worn and need replacement, or the pump pressure control switch could be defective and require replacement.
  • T
    Taylor SmithSep 7, 2025
    Why does the ball type shutoff close prematurely on my Tornado 98250 Floor Machine?
    • S
      Samantha PayneSep 7, 2025
      If the ball type shutoff is closing prematurely or failing to release after the recovery tank is drained on your Tornado Floor Machine, the shutoff filter screen might be dirty or clogged; remove and clean the screen. Alternatively, the ball could be coated with detergent or other foreign material; remove and rinse the ball with clean water. Lastly, the screen might be slightly out of round; bend the screen by squeezing slightly by hand until there is an obvious space between ball and inside of screen.
  • K
    Keith KirbySep 9, 2025
    Why is foam coming out of the vacuum exhaust port of my Tornado Floor Machine?
    • B
      Brenda EnglishSep 9, 2025
      If foam or dirty solution is coming out of the vacuum exhaust port of your Tornado Floor Machine, it could be due to foam carpet bypassing the water shutoff; use additional defoamer. Another possibility is that the elbow in the vacuum tank is not positioned correctly; the elbow should be pointed directly at the side wall of the tank away from the ball type shutoff.
  • A
    Amanda Dean MDSep 12, 2025
    What causes a leaking solution valve in my Tornado Floor Machine?
    • K
      kara62Sep 12, 2025
      If your Tornado Floor Machine has a leaking or stuck solution valve, it could be due to foreign material in the valve; remove the brass hex plug, clean the valve, and replace it. Alternatively, the brass hex nut might be loose; reseal the hex and plug. Finally, the valve or seals may be worn; replace worn parts with a solution valve repair kit.