Maintenance
Iftheextensioncordispluggedintoproduct,someonecould
accidentallyoperateitwhileyouareperformingmaintenance
onit,causingseriouspersonalinjury.
Disconnecttheextensioncordbeforeyouperformany
maintenance.
ReplacingtheRotor
Important:DisconnectthepowerfromthePowerShovelbefore
performingthisprocedure.
1.Usea9/16-inchwrenchtoremovetheboltonthesideofthe
housing.
2.Removetheoldrotorfromthehousing.
Figure8
3.Installthenewrotorinthehousingbyinsertingtheendoftherotor
ontothettedendinthehousingandrotatingtherotoruntilit
snapsintoposition.
Figure9
Note:Thehousingwillexwhenyouinstalltherotor.
4.Tightentheboltonthesideofthehousing.
Figure10
LubricatingthePowerShovel
ThePowerShoveldoesnotneedlubrication;allbearingsarelubricated
atthefactoryforthelifeoftheproduct.
Service
Torohasdesignedthisproducttogiveyouyearsoftroublefreeuse.
Shoulditneedservice,bringtheproducttoyourAuthorizedToro
ServiceDealer.YourToroDealerisspeciallytrainedtorepairToro
productsandwillensurethatyourTorostays“All”Toro.
Double-insulatedAppliances
Inadouble-insulatedappliance,twosystemsofinsulationare
providedinsteadofgrounding.Nogroundingmeansisprovidedon
adouble-insulatedappliance,norshouldameansforgrounding
beaddedtotheappliance.Servicingadouble-insulatedappliance
requiresextremecareandknowledgeofthesystem,andshouldbe
doneonlybythequaliedservicepersonnelatyourAuthorizedToro
ServiceDealer.Replacementpartsforadouble-insulatedappliance
mustbeidenticaltothepartstheyreplace.Adouble-insulated
applianceismarkedwiththewords“DoubleInsulation”or“Double
Insulated.”Thesymbol(squarewithinasquare)
mayalsobe
markedontheappliance.
ProductInformation
Amodelandserialnumberdecalislocatedonthehousing.Always
refertospecicnumbersothedecalincorrespondenceorwhenyou
needreplacementparts.