HydrostaticDriveTransmissionRemoval(continued)
g321834
Figure65
9.Disconnecttheconnectorssecuringtheoverowtubetothechassis.
Note:Overowtubesshouldstayconnectedtothetopofthetransmission.
Toavoidoilleaking,keeptheoverowtubesorientedup.
g321831
Figure66
10.Removethe4bolts(2boltsperside)securingthetransmissiontothehydro
crossplate.
11.Loosenthe4outerframemountingbolts(2boltsperside).
12.Loosenthe2boltsconnectingthetransmissiontotherearcrossmember.
13.Removethefrontmountingbolt.
14.Supportthetransmissionandremovethemountinghardware.Lowerthe
transmission.
TitanServiceManual
Page6–11
HydrostaticDriveSystem:ServiceandRepairs
3438-774RevA