i
OSMAC
®
G3 Satellite
User’s Guide
The OSMAC
®
G3 offers intuitive faceplate capabilities,
superior diagnostics and can be installed as a
complete satellite or as a retrofit faceplate upgrade
for existing E-OSMAC
®
satellites.
16 to 64 stations in 8-station increments
Field programmable for future upgrades
Operates as a stand-alone controller or
under the management of a central computer
Supports radio communications with the
central computer
12 irrigation programs
Independent stand-alone and central operation
Multi-Manual, Program Start and Syringe manual
operations
Operates up to 16 stations simultaneously
Question and Answer IconNeed help?

Do you have a question about the Toro OSMAC G3 and is the answer not in the manual?

Toro OSMAC G3 Specifications

General IconGeneral
BrandToro
ModelOSMAC G3
CategoryMarine Radar
LanguageEnglish

Summary

Introduction

Home Screen Overview

Accesses menus and settings from the home display.

Menu Navigation Controls

Explains the function of Select, Up, Down, Left, and Right buttons.

Operating Modes

Central Mode Operation

Satellite waits for and executes radio commands from the central.

Local Mode Operation

Executes scheduled and manual watering; ignores radio commands.

Off Mode Operation

Disables all watering operations, scheduled or manual.

Setting Clock and Mode

Setting the Clock Time

Adjusts the hour and minute parameters for the clock.

Setting Clock Format

Selects between Am/Pm (12-Hour) or 24 Hrs format.

Setting the Date

Sets the day, month, and year parameters.

Setting Date Format

Selects between MMDDYY or DDMMYY format.

Setting Scheduled Watering Programs

Program Designation

Selects or edits a specific program (up to 12).

Setting Watering Percentage

Adjusts the watering percentage from 10% to 250%.

Setting Active Watering Days

Assigns specific days or intervals for watering.

Setting Scheduled Start Times

Sets up to 24 start times for a program.

Assigning Stations and Runtimes

Assigns stations and their specific runtimes.

Setting Max Simultaneous Stations

Sets the maximum number of stations active at once (up to 16).

Configuring Radio Communications

Setting Satellite Address

Assigns a unique identification address to each satellite.

Setting Satellite Radio Frequency

Selects or edits the radio frequency for communication.

Settings Menu Options

Configuring Station Settings

Configures each station as an irrigation station or a switch.

Disabling Station Operation

Disables a station from activation indefinitely.

Configuring Station as Switch

Sets a station to activate relays or other devices, not pump.

Monitoring Scheduled Watering Today

Indicates if a station is set to irrigate today.

Monitoring Watering Today

Indicates if a station was activated today.

Monitoring Watering Yesterday

Indicates if a station watered the day before.

Resetting All Programs

Resetting Station Defaults

Resetting Controller to Factory Defaults

Enabling All Stations

Setting Clock Time

Setting Clock Format

Setting Date Format

Setting the Date

Setting Satellite Address

Setting Maximum Simultaneous Stations

Adjusting Display Contrast

Radio Settings Configuration

Selecting Radio Frequency

Selects from preprogrammed frequencies or edits custom frequencies.

Accessing Radio Information

Displays radio model, firmware, serial number, and RSSI.

Log All Sat Setting

Used for troubleshooting at the direction of Toro support.

RSSI Enable Setting

Used for troubleshooting at the direction of Toro support.

Resetting Radio Defaults

Resets all radio communication parameters to factory defaults.

Manual Watering Operations

Manual Station Watering

Manually starts a station or stations with a specified runtime.

Manual Program Start

Manually starts a scheduled program before its set start time.

Communication Features

Syringe Watering

Manually starts a scheduled program with a different runtime.

Page Monitor

Monitors real-time radio page commands for troubleshooting.

Page History

Reviews all received radio page commands.

Radio Menu

Duplicate of Radio Settings section, see page 12.

Satellite Address Configuration

Sets/edits the satellite's address for communication.

Setting Communication Mode

Monitoring Watering Activity

Diagnostic Information

Firmware Revision Information

Displays firmware version number and creation date.

Event Codes

Displays diagnostic codes encountered by the controller.

VA Monitor Readings

Displays real-time values like radio voltage, battery voltage, RSSI.

Station Test Function

Tests controller outputs, including pump and stations.

Sequential Station Test

Tests all OSMAC G3 stations sequentially.

Product Specifications

Electromagnetic Compatibility