3.Withtheauger/impellerleverdisengaged,ensurethat
thegapbetweentheaugerclutchassemblyandthetab
is1/16inch(1.5mm)(Figure48).
Figure48
1.Tab
2.1/16inch(1.5mm)
4.Iftheauger/impellercableisnotproperlyadjusted,do
thefollowingsteps:
5.Loosenthejamnut(Figure49).
Figure49
1.Jamnut2.Turnbuckle
6.Loosenortightentheturnbucklethatadjuststhe
tensiononthecable(Figure49).
7.Adjusttheturnbuckleuntilyouobtainthepropergap.
8.Tightenthejamnut.
9.Insertthe2screwsyoupreviouslyremovedonthebelt
cover.
10.Iftheauger/impellercableisproperlyadjustedbut
aproblemremains,contactanAuthorizedService
Dealer.
CheckingtheAugerGearbox
OilLevel
ServiceInterval:Yearly—Checktheaugergearboxoiland
addoilifnecessary.
1.Movethemachinetoalevelsurface.
2.Cleantheareaaroundthepipeplug(Figure50).
1
G016782
Figure50
1.Pipeplug
3.Removethepipeplugfromthegearbox.
4.Checktheoillevelinthegearbox.Theoilshouldbeat
thepointofoverowingatthelleropening.
5.Iftheoillevelislow ,addGL-5orGL-6,SAE85-95
EPgearoillubricanttothegearboxuntilthepointof
overow .
Note:Donotusesyntheticoil.
6.Installthepipepluginthegearbox.