ServicingtheFoamAir-Cleaner
Element
ServiceInterval:Every25hours/Monthly(whichever
comesrst)—Cleantheair-cleaner
foamelement(moreoftenindusty,
dirtyconditions).
Every100hoursoryearly,whichevercomes
rst—Replacetheair-cleanerfoamelement
(moreoftenindusty,dirtyconditions).
1.Washthefoamelementinliquidsoapand
warmwater.Whentheelementisclean,rinse
itthoroughly.
2.Drytheelementbysqueezingitinacleancloth.
Important:Replacethefoamelementifit
istornorworn.
ServicingthePaperAir-Cleaner
Element
ServiceInterval:Every100hoursoryearly,
whichevercomesrst—Replacethe
paperair-cleanerelement(more
oftenindirtyordustyconditions).
1.Cleanthepaperelementbytappingitgentlyto
removedust.
Note:Ifitisverydirty,replacethepaper
elementwithanewone.
2.Inspecttheelementfortears,anoilylm,or
damagetotherubberseal.
3.Replacethepaperelementifitisdamaged.
Important:Donotcleanthepaperlter.
InstallingtheAirCleaner
1.Installthefoamelementoverthepaperelement.
Note:Ensurethatyoudonotdamagethe
elements.
2.Aligntheholesofthelterintothemanifold
ports.
3.Rotatethelterdownintothechamberandfully
seatitagainstthemanifold(Figure38).
g228022
Figure38
4.Closethecover.