SPECIFIC INFORMATIONS
13
CHAPTER 2 SPECIFIC INFORMATIONS
SETTING & ADJUSTING DATA
SAFETY INSTRUCTIONS
SERVICE MODE
ADJUSTING ITEMS AND DATAS IN THE SERVICE MODE:
Table-1
Table-2
21"
HIGH VOLTAGE AT ZERO BEAM: (A) 30.0 kV
MAX HIGH VOLTAGE: (B) 32.0 kV
AC VOLTAGE (C) 110-240 V
RCUT R CUTOFF (B/W) 20H
GCUT G CUTOFF (B/W) 20H
BCUT B CUTOFF (B/W) 20H
GDRV G DRIVE 40H
BDRV B DRIVE 40H
BRTC SUB BRIGHT CEN 40H
COLC SUB COLOR CEN NTSC 30H
TNTC SUB TINT CEN 45H
COLP SUB COLOR CEN PAL 09H
COLS SUB COLOR CEN SECAM 30H
SCNT SUB CONTRAST 08H
HPOS 50Hz H-POSITION 0DH
VPOS V-POSITION 04H
HIT HEIGHT 1EH
VLIN V-LINEARITY 0AH
SBY SECAM R-Y 08H
SRY SECAM-B-Y 08H
RAGC RF AGC 2AH
Item
Adjustment Reference data
Data