13
GENERAL ADJUSTMENTS
SPECIFIC INFORMATIONS
SETTING & ADJUSTING DATA
21"
HIGH VOLTAGE AT ZERO BEAM: (A) 29.1 kV
MAX HIGH VOLTAGE:
(B) 31.3 kV
AC VOLTAGE
(C) 110~240 V
CHAPTER 2 SPECIFIC INFORMATIONS
SAFETY INSTRUCTIONS
Table-1
SERVICE MODE
ADJUSTING ITEMS AND DATAS IN THE SERVICE MODE:
Table-2
DESIGN MODE
ADJUSTING ITEMS AND DATAS IN THE DESIGN MODE:
Data
Item Name of adjustment
Preset Data 21"
Remarks
Table-3
Item Adjustment Reference data
RCUT
GCUT
BCUT
GDRV
BDRV
BRTC
COLC
TNTC
COLP
COLS
SCNT
HPOS
VPOS
HIT
VLIN
WID
PARA
CNR
TRAP
SRY
SBY
R CUTOFF (B/W)
G CUTOFF (B/W)
B CUTOFF (B/W)
G DRIVE
B DRIVE
SUB BRIGHT CEN
SUB COLOR CEN NTSC
SUB TINT CEN
SUB COLOR CEN PAL
SUB COLOR CEN SECAM
SUB CONTRAST
50Hz H-POSITION
V-POSITION
HEIGHT
V-LINEARITY
PICTURE WIDTH
E-W PARABOLA
E-W CORNER
TRAPEZIUM
SECAM R-Y
SECAM-B-Y
20H
20H
20H
40H
40H
40H
30H
45H
00H
30H
08H
0DH
04H
1EH
0AH
30H
15H
05H
0DH
08H
08H
Data
09H
2EH
34H
15H