e-STUDIO163/203 ERROR CODE AND SELF-DIAGNOSTIC MODE December 2005 © TOSHIBA TEC
2 - 6
OFF [7]
0- --
1- --
2- --
3- --
4- --
5 PFU feed sensor Paper present No paper
6 PFU drawer detection switch No drawer Drawer present
OFF [8]
0 Toner cartridge detection switch No cartridge Cartridge
present
1- --
2 Polygonal motor rotation status (Motor is
rotating at Output Mode (04))
Abnormal rota-
tion
Normal rotation
3- --
4 PFU board connection Not connected Connected
5- --
6 24 V power supply
(Front cover opening/closing)
24 V ON 24 V OFF
OFF [9]
0- --
1- --
2 PFU cover opening/closing switch Cover opened Cover closed
3 Front cover opening/closing switch Cover opened Cover closed
4- --
5 Exit sensor Paper present No paper
6 Registration sensor Paper present No paper
OFF [0]
0- --
1- --
2- --
3 Developer unit switch Not connected Connected
4 Fuser unit switch Connected Not connected
5- --
6 Externally counter connection Not connected Connected
[INTER
RUPT]
LED
Number
[Digital
keys]
Display
position
of the
density
LED
Items to check ON OFF