e-STUDIO163/203 ADJUSTMENT December 2005 © TOSHIBA TEC
3 - 4
[Procedure to key in adjustment values]
In accordance with the procedure described below, make adjustment of each adjustment item so that
the measured values obtained from test copies satisfy the specification.
Fig. 3-5
[0][5]
[0][9]
[
POWER
]
[
INTERRUPT
]
[
Digital keys
]
[
START
]
:Enter the code.
:Current adjustment
value is displayed.
<
Operation keys> <Display>
:Exit the Adjustment Mode.
OFF/ON
:Move to the normal
mode.
[0][5]
:Move to the adjustment
mode.
[
Digital keys
]:
Enter adjustment values.
([CLEAR] Use to make corrections)
[
Power
]
Test copy
1
If the test copy does not
satisfy the specified values,
return to step 1 and
repeat the adjustment
procedure.