ADJUSTMENT
3 - 40
3.7.3 Scan motor (CIS unit drive belt-2)
When installing the scan motor and CIS unit drive belt-2, adjust the tension of the CIS unit drive belt-2
with the belt tension jig.
<Procedure>
(3) Tighten screws A and B where the scan motor pulled by the belt tension jig stops.
(1) Temporarily fix screws A and B.
Fig. 3-26
(2) Hook the belt tension jig on the motor
bracket and frame.
Fig. 3-27
A
Scan motor
B
Scan motor
Belt tension jig