TROUBLESHOOTING
5 - 31
5
11)Skew (inclined image)
Fig. 5-11
Defective area Step Check items Prescription
Drawers 1 Is the drawer properly installed? Install the drawer properly.
2 Is there too much paper in the
drawer?
Reduce paper to 250 sheets or less.
3 Is the corner of the paper folded? Change the direction of the paper
and set it again.
4 Are the side guides of the drawer
properly installed?
Adjust the position of the side guides.
Feed roller 5 Is the surface of the feed roller dirty? Clean the feed roller surface with
alcohol, or replace the roller.
Rollers 6 Are the roller and shaft secured? Check and tighten the E-rings, pins,
clips and setscrews.
Registration roller 7 Is the spring detached from the regis-
tration roller?
Attach the spring correctly. Clean the
roller if it is dirty.
Pre-registration guide 8 Is the pre-registration guide properly
installed?
Correct it.
CIS unit 9 Is the CIS unit slanted? Replace the CIS case.
Feed system 10 Is the aligning amount proper? Adjust the aligning amount.