© 2005 - 2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO163/166/203/206
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 33
2
2.2.8 Setting mode (08)
Note: Note:
When inputting a 4-digit code (ie. 1000 to 1999), press the [%] button instead of “1” for the thou-
sand’s place, and then key in the other 3 digits.
E.g.) 1372: [%] -> [3] -> [7] -> [2]
Classification List of Setting Mode (08)
The items in the setting code list can be set or changed in this setting mode (08).
Classification Setting Mode (08)
ADF [Switchback] 462
Counter [Double count] 345,346,347,348,349,352,353
[Total Counter copy] 388,389
[Toner cartridge] 1410
[External counter] 381, 975
[Paper source] 356,357,358,374
[Fuser unit] 1372,1378,1380,1382
[Media type] 1385,1386,1388,1411
Image
[Error diffusion / Dither] 502
[Default setting] 538,550
Paper feeding
[change of paper source] 481
[Retry] 482
[Default setting] 480
[Paper exit] 698,699
[Paper size] 224,226
[Paper dimension] 229-0 to 1,230-0 to 1,231-0 to 1,232-0 to 1,
233-0 to 1,234-0 to 1,235-0 to 1,236-0 to 1,
237-0 to 1,238-0 to 1,239-0 to 1,240-0 to 1,
241-0 to 1,242-0 to 1,244-0 to 1,245-0 to 1,
337-0 to 1,338-0 to 1,339-0 to 1,340-0 to 1,
341-0 to 1,471-0 to 1
Development
[Auto-toner] 414
[Developer bias] 833,834,835,836,837,840,858,859,860,861,862,863
General
[Reset] 655
[Toner cartridge check] 695
[Nearly empty] 971
[Page setting] 949
[Line] 203
[Access code] 672
Scanner [Control status] 463
Main charger bias [Main charger bias] 805,806,807,808,809,814,819,826,864,865,866,867
Fuser
[Pre-running] 439,440,441,523,526
[Temperature] 404-0 to 3,405-0 to 3,407,409,410,411,413,
424-0 to 3,425-0 to 3,433-0 to 1,437,438,448,450,451,
452,453,476-0 to 3,515,516,520,521,525-0 to 3,
527-0 to 3,535-0 to 1,536-0 to 3,537-0 to 3,
539-0 to 3,540-0 to 3,541-0 to 3,800-0 to 1,
801-0 to 1,802-0 to 1,804-0 to 1,886,896-0 to 1
[Status counter] 400
Transfer bias [Transfer bias] 830,868,869
Separation bias [Separation bias] 831,870,871
07/02