e-STUDIO181/211 © 2009 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 42
(7) Insert the gauge “0.40” of the doctor sleeve
jig into the gap between the developer
sleeve and doctor blade. Confirm that the jig
moves smoothly to the front and rear side,
and the gauge “0.50” cannot be inserted into
the gap.
Fig. 3-34
(8) Confirm that the side seals are attached on
the toner scattering prevention sheet.
Fig. 3-35
(9) Attach the developer unit upper cover and
tighten 2 screws.
Note:
After the developer material has been
replaced, adjust the auto-toner sensor.
(See P.3-1 "3.1 Adjustment of Auto-Toner
Sensor".)
Fig. 3-36
Developer
sleeve
Doctor sleeve jig
Side seal
Toner scattering
prevention sheet
Developer
unit upper cover