381 Counter Setting for counter installed
externally
ALL 1
<0-1>
M Selects the job to count
up for the external
counter.
0: Not selected
1: Copier
1
388 Counter Copying total counter /
MAIN board → SRAM
board
ALL - - Copies the total counter
value of the MAIN
board to the SRAM
board.
15
389 Counter Copying total counter /
SRAM board → MAIN
board
ALL - - Copies the total counter
value of the SRAM
board to the MAIN
board.
15
400 Fuser Fuser unit error status
counter
ALL 0
<0-19>
M0:No error
1: C41 (Once)
2: C41 (consecutively
occurred)
3: C46 4: C43
5: C44 6: C45
7: C44 8: C45
9: C44 10: C47
11: C47 12: C48
13: C49 14: C47
15: C48 16: C49
17: C47 18: C48
19: C49
1
404-0 Fuser Temperature
drop setting in
ready status
(Center
thermistor)
The first
drop
ALL 1
<0-10>
M This code is valid only
when “20” is set to 08-
886.
Setting value x -5°C:
from 0°C to -50°C
4
404-1 The
second
drop
ALL 1
<0-10>
M4
404-2 The third
drop
ALL 1
<0-10>
M4
404-3 The fourth
drop
ALL 1
<0-10>
M4
405-0 Fuser Temperature
drop setting in
ready status
(Side
thermistor)
The first
drop
ALL 3
<0-10>
M4
405-1 The
second
drop
ALL 3
<0-10>
M4
405-2 The third
drop
ALL 3
<0-10>
M4
405-3 The fourth
drop
ALL 3
<0-10>
M4
407 Fuser Fuser roller temperature in
ready status
(Side thermistor)
ALL 6
<0-12>
M 0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
1
409 Fuser Fuser roller temperature at
energy saver mode
(Center thermistor)
ALL EUR: 7
Other: 0
<0-13>
M 0: OFF 1: 40°C
2: 50°C 3: 60°C
4: 70°C 5: 80°C
6: 90°C 7: 100°C
8: 110°C 9: 120°C
10: 130°C
11: 140°C
12: 150°C
13: 160°C
1
Setting mode (08)
Code
Classific
ation
Items
Funct
ion
Default
<Accept
able
value>
RAM Contents
Proce