2
© 2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO181/211
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 41
410 Fuser Fuser roller temperature
during printing
(Center thermistor/Plain
paper)
ALL 6
<0-14>
M 0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
1
411 Fuser Fuser roller temperature on
standby
(Center thermistor)
ALL 6
<0-12>
M 0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
1
413 Fuser Fuser roller temperature
during printing
(Center thermistor/Thick
paper 1)
ALL 6
<0-14>
M 0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
1
414 Develop
er
Toner density life
correction switching
ALL 0
<0-7>
M 0: Unchanged (Default)
1: Approx. 0.1 wt%
lower
2: Approx. 0.2 wt%
higher
3: Approx. 0.5 wt%
higher
4: Approx. 0.6 wt%
lower
5: Approx. 0.8 wt%
lower
6: Approx. 1.0 wt%
lower
7: Approx. 1.3 wt%
lower
1
424-0 Fuser Temperature
drop switching
time setting in
ready status
(Center
thermistor)
The first
drop
ALL 15
<2-60>
M This code is valid only
when “20” is set to 08-
886.
Setting value x 1 min.:
from 2 to 60 min. later
4
424-1 The
second
drop
ALL 15
<2-60>
M4
424-2 The third
drop
ALL 15
<2-60>
M4
424-3 The fourth
drop
ALL 15
<2-60>
M4
425-0 Fuser Temperature
drop switching
time setting in
ready status
(Side
thermistor)
The first
drop
ALL 15
<2-60>
M4
425-1 The
second
drop
ALL 15
<2-60>
M4
425-2 The third
drop
ALL 15
<2-60>
M4
425-3 The fourth
drop
ALL 15
<2-60>
M4
Setting mode (08)
Code
Classific
ation
Items
Funct
ion
Default
<Accept
able
value>
RAM Contents
Proce
dure